Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
Similar figure image 1

Circuit breaker, S00, motor protection, Class 10, A-release 0.35-0.5 A, short...

En stock: Non Stock fournisseur: Oui Quantité minimale de commande: 1
Prix (hors TVA):
26,94 € par pièce
Ce prix est valable jusqu’au 24.12.25
EAN: 4011209712362
MPN: 3RV2011-0FA10
Boîte: 1
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.35...0.5 A N-release 6.5 A
Marque Siemens
Catégories Motor protection circuit-breakers
Pays d’origine DE
Code du système harmonisé 8536 2010 00
Largeur 45 mm
Hauteur 97 mm
Profondeur 97 mm
Puissance nominale de fonctionnement à AC-3, 400 V 0.12 kW
Avec interrupteur auxiliaire intégré No
Courant permanent nominal Iu 0.5 A
Avec déclencheur de sous-tension intégré No
Nombre de pôles 3
Tension nominale de fonctionnement 690 V
Réglage du courant de déclenchement de la surcharge 0.35-0.5 A
Degré de protection (IP) IP20
Avec protection thermique -
Puissance nominale de fonctionnement à AC-3, 230 V 0.1 kW
Pouvoir de coupure nominale en cas de court-circuit lcu à 400 V, AC 100 kA
Plage de réglage du déclenchement non temporisé en cas de court-circuit UN A
Sensible aux défaillances de phase Yes
Construction de l'appareil Dispositif à encastrer technique d'encastrement fixe

Détails d’emballage

Niveau d’emballage 1 4011209712362

Description

Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.35...0.5 A N-release 6.5 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, the compact and climate-resistant circuit breakers are optimized for use in load feeders, and also for IE3/IE4 motors, of course, and equally for the switching of direct current. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date - SIRIUS modular system.