Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Sylvania Light ribbon-/hose/-strip

Ceilings, coves, and façades behave only when strips, drivers, and profiles are specified as one system. Sylvania’s tape families keep commissioning tidy on 24/48 V DC rails, with predictable current per metre, tight colour bins, and accessories that survive site handling. Expect efficacy 90–160 lm/W (model dependent), CRI 80/90/95 options with R9 > 50 on premium lines, CCT sets from 2200–6500 K, tunable-white (TW), RGB/RGBW/RGBCCT, and IP20/IP65/IP67/IP68 builds. LM-80/TM-21 data underpins lifetime claims; thermal design assumes aluminium profiles for anything above ~10 W/m.

sylvania light ribbon hose strip range and formats

Widths 5/8/10/12 mm, pitches 60/120/180/240 LEDs/m, and cut steps typically 25/50/100 mm cover furniture to atrium runs. High-output rails push 14–28 W/m for feature walls; economy bands sit 4–10 W/m for guidance light. Constant-voltage at 24 V is the baseline for voltage-drop control; 48 V extends run length on long coves. For planners, sylvania light ribbon hose strip marks SKUs that share connectors and profiles so crews aren’t mixing parts at height.

sylvania led ribbon hose electrical and control

Constant-voltage strips pair with DALI-2/1–10 V/PWM drivers; pixel variants accept SPI/DMX for media façades. PF ≥ 0.95 on quality drivers, THD ≤ 10–15 %, surge protection sized to the feeder. Feed both ends beyond ~5 m or home-run back to a distribution bar; keep voltage drop under 3 %. Where corridors need stand-by levels, sylvania led ribbon hose works cleanly with corridor dimming curves and daylight tracking on the same bus.

sylvania flexible light strip optics and colour

MacAdam ≤ 3-step bins keep tone consistent across phases; CRI 90/95 lines hold R9 on timber and fabrics; low-blue 2700–3000 K options support hospitality briefs. Diffusers include opal and micro-prism; dotted-free (“COB”) variants remove diode imaging at shallow offsets. When designers tag sylvania flexible light strip, they lock lumen band, beam control via profile, and CCT across rooms so ceilings read as one surface.

sylvania decorative ribbon lighting mechanical and IP

PCB copper 2–3 oz rides out current and reduces hotspots; minimum bend radius ~20–30 mm (tighter on thin tapes). IP builds: IP20 for dry coves, IP65 silicone topcoat for wipe-down, IP67/68 extrusions for façades. Adhesives are 3M 300LSE/VHB; always pair with mechanical retention in warm ceilings. In lobby features and reveals, sylvania decorative ribbon lighting uses rigid profiles and glare-cut lips to keep lines crisp without pixel read-through.

sylvania linear led strips installation and thermal practice

Profiles in anodised aluminium with snap diffusers move heat into the substrate; expect ~3–6 K/W improvement vs bare tape. Pre-wire harnesses with polarity-keyed plugs and IP-rated joiners; 0.5…2.5 mm² copper sized from run length and load. Keep SELV segregation, earth any metal profile, and label cut steps at handover. Facilities standardise sylvania linear led strips by wattage band and profile family to stabilise spares.

sylvania led hose lights applications and run design

Retail shelves want asymmetric lips for vertical lux; offices use shallow channels for halo lines; hotels run warm white perimeters with TW scenes for events; façades need UV-stable silicone and drainable extrusions. Emergency egress remains upstream of dimming. In multi-phase programmes, sylvania led hose lights hit kWh targets with calm dimming and repeatable geometry.

sylvania lighting accessories strip kitting and connectors

End caps, corner pieces, snap joiners, feed tails, suspension clips, and lens options share hole geometry and thread sizes; gaskets are closed-cell EPDM/silicone. IP ratings hold when ferrules match jacket OD and torque is verified. Procurement bundles sylvania lighting accessories strip by room type so night crews aren’t chasing small parts during handover.

Technical specifications and standards

  • Electrical: 24/48 V DC constant-voltage rails; current per metre declared; drivers to EN 61347; PF ≥ 0.95; THD ≤ 10–15 %.
  • Photometric: 2200–6500 K, TW, RGB/RGBW/RGBCCT; CRI 80/90/95; ≤ 3-step SDCM; 90–160 lm/W typical; flicker-safe PWM options.
  • Mechanical/IP: widths 5–12 mm; cut 25/50/100 mm; bend radius 20–30 mm; IP20/65/67/68; adhesives 3M 300LSE/VHB plus mechanical retention.
  • Environment: −20…+50 °C operation; UV-stable silicone for exteriors; ammonia-resistant parts on request.
  • EMC/safety: EN 62031 LED modules, EN 60598 luminaires, EN 55015/EN 61000-3-2 EMC, IEC 60529 IP; photobiological EN 62471.

Applications and compatibility

  • Offices/education: continuous lines with UGR-friendly profiles; daylight harvesting and corridor hold (10–30 %).
  • Retail/hospitality: CRI 90/95, warm whites, dotted-free COB near glossy finishes.
  • Residential/mobility cores: low-glare guidance; sealed joins for wet areas.
  • Façades/canopies: IP67/68 extrusions, drain paths, UV-stable encapsulation, coordinated surge at cabinet/head.

Integration with other Sylvania categories

Tie strips to Sylvania automatics and control so scenes, daylight, and schedules share a DALI-2 or 0–10 V backbone. Pair with Sylvania profiles and drivers to keep thermal margins and inrush predictable; match CCT/CRI with adjacent pendants or panels for visual continuity.

Selection criteria for B2B clients

  1. Define task: accent vs general vs guidance; set target lux and uniformity.
  2. Choose wattage band and profile for thermal and glare control; confirm bend radius and cut step.
  3. Fix interface (DALI-2/0–10 V/PWM/DMX), driver location, and emergency strategy.
  4. Engineer runs: wire gauge, feed points, voltage drop < 3 %, IP class by location.
  5. Document kitting: connectors, caps, lenses, labels, and acceptance tests (flux, CCT, insulation, pull-off on adhesive).

Advantages of working with Bankoflamps

We price by room bundle and expose live EU stock before ceilings are opened. Quotes land in roughly an hour with EAN/MPN so variants stay locked. Your portal shows lead times, shipment status, and downloadable price lists with planning-grade validity. Approved clients can use post-payment up to 30 days. We consolidate partials to cut freight, and your account manager cross-checks driver interface, wattage/m run, profile choice, IP kit, connector family, and label sets against your drawings so cartons arrive site-ready across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.