Technical Information
| État de l’article |
Nouveau |
| Nom du fabricant |
VIGIREX RH197M 220-240VAC 50/60/400HZ |
| Marque |
Schneider Electric
|
| Catégories |
Monitoring Relays
|
| Pays d’origine* |
IT |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Code du système harmonisé |
8536 4900 00
|
| Fonction |
Pour système d'alimentation triphasé |
| Enregistrement d'erreurs possible |
No |
| Indication de la différence de courant |
No |
| Valeur de réponse ampérage 1 |
0-30 mA |
| Valeur de réponse ampérage 2 |
0-30000 mA |
| Nombre de contacts comme contact normalement fermé |
1 |
Détails d’emballage
| Niveau d’emballage 1 |
3606480359743 |
Autres données techniques
| Largeur |
54 mm |
| Hauteur |
97 mm |
| Profondeur |
74 mm |
| Fréquence nominale |
50-400 Hz |
| Avec pinces détachables |
No |
| Type de connexion électrique |
Raccordement à vis |
| Tension nominale |
230 V |
| Tension nominale d'alimentation de commande Us à AC 50HZ |
220-240 V |
| Tension nominale d'alimentation Us à AC 60HZ |
220-240 V |
| Durée maximale autorisée de la temporisation à l'enclenchement |
4.5 s |
| Temps de retard à l'enclenchement réglable au minimum |
0 s |
| Type de tension pour l'actionnement |
AC |
| Nombre de contacts comme contact normalement ouvert |
1 |
| Nombre de contacts comme contact inverseur |
1 |
Description
RH197M is a DIN rail mounting residual current protection relay. It protects against people direct or indirect contact, property fire hazards and motors. It measures the earth leakage current in an electrical installation via its associated toroid. It trips the associated circuit breaker when the set residual operation current is overrun. The operational supply voltage is from 220 VAC to 240 VAC 50/60Hz. The current sensitivity is selectable with 19 thresholds from 30 mA to 30 A. The time delay is selectable with 7 settings from instantaneous to 4.5s. The alarm is set by Dip switch at 50% or 100% of IDn. A switch make the selection between local manual reset or automatic reset after a fault clearance. The monitored distribution system voltage is up to 1000 VAC 50/60/400 Hz. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric toroid. It is installed on a DIN-rail inside a switchboard and the protection degree is IP40. It must be associated with a compatible Schneider Electric type A toroid or rectangular sensor.