Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24 image 1
Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24 image 2
Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24 image 3
Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24 thumbnail 1
Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24 thumbnail 2
Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24 thumbnail 3

Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24

Commande uniquement Non disponible
Délai de livraison estimé à notre entrepôt: Sur demande

Technical Information

État de l’article Nouveau
Nom du fabricant Undervoltage release for NZM4, 1 early-make auxiliary contact, 2NO, 24
Marque EATON
Pays d’origine* RO
* Le pays d'origine réel peut varier selon le lot de livraison. Pour confirmer le pays d'origine spécifique, veuillez contacter votre gestionnaire de compte.
Code du système harmonisé 8538 9099 00
ETIM EC001022
Type de connexion électrique Raccordement à vis
Tension nominale d'alimentation de commande Us à AC 50HZ 24 V
Tension nominale d'alimentation Us à AC 60HZ 24 V
Tension nominale d'alimentation de commande Us à DC 0 V
Type de tension pour l'actionnement AC

Détails d’emballage

Niveau d’emballage 1 4015081877812

Autres données techniques

Retardé No
Adapté à l'interrupteur de décharge Yes
Adapté au relais de surcharge No
Adapté à l'interrupteur de sécurité du moteur Yes
Convient pour les disjoncteurs de puissance No
Nombre de contacts comme contact normalement fermé 0
Nombre de contacts comme contact normalement ouvert 1
Nombre de contacts comme contact inverseur 0

Description

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Undervoltage releases with one early-make contact and push-in terminals. For interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in main-switch applications. Non-delayed disconnection of circuit-breaker NZM when control voltage drops below 35 - 70 % Us. For use with emergency switching off devices in conjunction with emergency switching off buttom . When the undervoltage release is de-energized, accidental contact with the main contacts of the circuit-breaker dureing attempts to switch on is reliably prevented. Early-make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms (NZM2/3) and 90 ms (NZM4). Undervoltage release modules cannot be installed simultaneously with early-make contact NZM…-XHIV, shunt release NZM…-XA… or relais modules NZM...-X2A...