Undervoltage release for NZM2/3, configurable relays, 2NO, 208-240AC, Push-in terminals
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 24.12.25
Délai de livraison estimé à notre entrepôt (environ):
4-6 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
NZM2/3-XU2A208-240AC Undervoltage release for NZM2/3, configurable relays, 2NO, 208-240AC, Push-in terminals |
Marque |
EATON
|
Catégories |
Trip & Release Units
|
Pays d’origine |
RO |
Code du système harmonisé |
8538 9099 00
|
Type de connexion électrique |
Raccord à ressort |
Tension nominale d'alimentation de commande Us à AC 50HZ |
208-240 V |
Tension nominale d'alimentation Us à AC 60HZ |
208-240 V |
Tension nominale d'alimentation de commande Us à DC |
0 V |
Type de tension pour l'actionnement |
AC |
Détails d’emballage
Niveau d’emballage 1 |
4015081877225 |
Autres données techniques
Retardé |
No |
Adapté à l'interrupteur de décharge |
Yes |
Adapté au relais de surcharge |
No |
Adapté à l'interrupteur de sécurité du moteur |
Yes |
Convient pour les disjoncteurs de puissance |
No |
Nombre de contacts comme contact normalement fermé |
0 |
Nombre de contacts comme contact normalement ouvert |
2 |
Nombre de contacts comme contact inverseur |
0 |
Description
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Undervoltage releases with two relays. Non-delayed disconnection of circuit-breaker NZM when control voltage drops below 35 - 70 % Us. For use with emergency switching off devices in conjunction with emergency switching off buttom. For signalizing commands or different states of the circuit-breaker. Two relays per unit. Actuation reason can be configured in the trip unit . Configuration via communication or circuit breaker display or front USB connection and Eaton Power Xpert Protection Manager. When the undervoltage release is de-energized, accidental contact with the main contacts of the circuit-breaker dureing attempts to switch on is reliably prevented. Only suitable for use in conjunction with circuit-breakers with electronic releases. Undervoltage release relais modules cannot be installed simultaneously with early-make contact NZM…-XHIV, or untervoltage release NZM…-XU…, or shunt release NZM…-XA… Relay coil actuated by trip unit. Relay contact for control wiring. Control wiring to push-in terminals . Cannot be used with PXR10 NZM-AE electronic release.