Analogue settable time relay with clock generator, 1 CO contact 10A
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 31.12.25
Délai de livraison estimé à notre entrepôt (environ):
2-4 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
Analogue settable time relay with clock generator, 1 CO contact 10A |
Marque |
ELTAKO
|
Catégories |
Push Buttons and Control
|
Pays d’origine |
CN |
Code du système harmonisé |
8536 4900 00
|
Méthode de montage |
Rail DIN |
Fonction |
Minuterie de démarrage avec impulsion |
Type d'excitation |
Analogique avec fonction unique |
Largeur en nombre d'espacements modulaires |
1 |
Nombre d'inverseurs |
1 |
Type de tension d'alimentation |
AC/DC |
Tension d'alimentation |
8-230 V |
Unité du 1er intervalle |
Minutes/heures |
1er intervalle |
0.1-40 |
Capacité de commutation lampes à incandescence |
2000 W |
Capacité de commutation lampe fluorescente inductive |
1000 VA |
Nombre de contacts comme contact normalement fermé |
0 |
Nombre de contacts comme contact normalement ouvert |
0 |
Détails d’emballage
Niveau d’emballage 1 |
4010312603116, 4010312603116 |
Niveau d’emballage 2 |
4010312603116 |
Niveau d’emballage 3 |
4010312603116 |
Autres données techniques
Hauteur d'encastrement |
58 mm |
Tension de contrôle 1 |
8-230 V |
Type de tension de commande 1 |
AC/DC |
Tension de contrôle de la fréquence 1 |
50 Hz |
Capacité de commutation lampe fluorescente DUO |
1000 VA |
Capacité de commutation lampe fluorescente parallèle |
500 VA |
Téléchargements
Description
Clock generator starting with impulse, 1 CO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 2000W*. Standby loss 0.02-0.4 watt only. Modular devices for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. T1 and T2 can be set separately by a second multiplier while the time base remains the same. With the Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 15(L) for this. This gives an additional standby consumption of only 0.1 Watt. Universal control voltage 8 to 230V UC. Supply voltage same as the control voltage. Time setting between 0.1 seconds and 40 hours. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact 15-18 is open (15-16 closed), and is continuously ON as long as the relay contact 15-18 is closed (15-16 open). The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier. The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 seconds (time base 0.1 seconds and multiplier 1) and 40 hours (time base 4 hours and multiplier 10). * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.