Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 1
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 2
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 3
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 4
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 5
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 6
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 7
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 8
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 9
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 10
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 11
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 12
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 13
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 14
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 15
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets image 16
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 1
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 2
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 3
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 4
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 5
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 6
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 7
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 8
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 9
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 10
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 11
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 12
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 13
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 14
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 15
SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets thumbnail 16

SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
235,45 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4015081712199
MPN: 174733
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant SmartWire-DT IP67 T-Connector analog module, two configurable Pt100/Pt1000/Ni1000 temperature inputs, two M12 I/O sockets
Marque EATON
Catégories Programmable logic controllers
Pays d’origine MX
Code du système harmonisé 8471 8000 00
Largeur 56.9 mm
Hauteur 20.1 mm
Profondeur 98 mm
Adapté aux fonctions de sécurité No
Nombre d'entrées analogiques 2
Nombre de sorties analogiques 0
Type de tension d'alimentation DC
Protocole de support pour LON No
Nombre d'interfaces HW Ethernet industriel 0
Nombre d'interfaces HW RS-232 0
Nombre d'interfaces HW RS-422 0
Nombre d'interfaces HW RS-485 0
Nombre d'interfaces HW TTY série 0
Nombre d'interfaces HW USB 0
Nombre d'interfaces HW parallèles 0
Nombre d'interfaces HW autres 0
Protocole de support pour TCP/IP No
Protocole de support pour ASI No
Protocole de support pour PROFIBUS No
Protocole de support pour CAN No
Protocole de support pour INTERBUS No
Protocole de support pour KNX No
Protocole de support pour Modbus No
Protocole de support pour Data-Highway No
Protocole de support pour DeviceNet No
Protocole de support pour SUCONET No
Protocole de support pour d'autres systèmes de bus Yes
Entrée, courant No
Entrée, tension No
Entrée, résistance No
Entrée, thermomètre à résistance Yes
Entrée, thermocouple No
Signal d'entrée, configurable Yes
Sortie, courant No
Sortie, tension No
Signal de sortie configurable No
Résolution des entrées analogiques 12 Bit
Résolution des sorties analogiques 0 Bit
Type de connexion électrique Raccordement à vis
Possibilité de montage sur rail Yes
Catégorie de sécurité antidéflagrante pour le gaz Aucun
Catégorie de sécurité antidéflagrante pour les poussières Aucun
Possibilité de connexion au bus de terrain par l'intermédiaire d'un coupleur de bus séparé Yes
Accessoire du système Yes
Agent d'exploitation auxiliaire (Ex ia) No
Agent d'exploitation auxiliaire (Ex ib) No
Degré de protection (IP) IP69K
Protocole de support pour SERCOS No
Protocole de support pour INTERBUS-Safety No
Nombre d'interfaces PROFINET 0
Nombre d'interfaces HW Sans fil 0
Possibilité d'encastrement frontal No
Montage en rack possible No
Montage mural/montage direct Yes
Norme radio Bluetooth No
Norme radio Wi-Fi 802.11 No
Maître de liaison IO No
Niveau de performance selon EN ISO 13849-1 Aucun
Protocole de support pour AS-Interface Safety at Work No
Protocole de support pour DeviceNet Safety No
Protocole de support pour EtherNet/IP No
Protocole de support pour Foundation Fieldbus No
Protocole de support pour PROFINET CBA No
Protocole de support pour PROFINET IO No
Protocole de support pour PROFIsafe No
Protocole de support pour SafetyBUS p No
Tension d'alimentation AC 50 Hz 0 V
Tension d'alimentation AC 60 Hz 0 V
Tension d'alimentation DC 0 V
Entrées analogiques configurables Yes
Sorties analogiques configurables Yes
Norme radio GPRS No
Norme radio GSM No
Norme radio UMTS No
SIL selon IEC 61508 Aucun
Degré de protection (NEMA) 4X

Détails d’emballage

Niveau d’emballage 1 4015081712199

Description

SWD module with IP69K degree of protection for connecting up to two temperature sensors, automatic address setting, PT100 temperature sensor parameterizable, pt1000, NI1000, scan time and averaging parameterizable, –50 °C to +400 °C temperature range, I/O connection with 2/3-wire configuration with M12 socket for each input