Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
MD01 image 1
residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S image 2
residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S image 3
residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S image 4
MD01 thumbnail 1
residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S thumbnail 2
residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S thumbnail 3
residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S thumbnail 4

residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
1 975,49 €
Ce prix est valable jusqu’au 24.12.25
EAN: 3303430167655
MPN: 16765
Colis: 1
Boîte: 12
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant residual current circuit breaker ID - 4 poles - 125 A - class B 300 mA S
Marque Schneider Electric
Catégories Leakage protection
Pays d’origine DE
Méthode de montage Rail DIN
Type de tension AC
Profondeur d'encastrement 44 mm
Courant nominal 125 A
Tension nominale 400 V
Tension nominale d'isolation Ui 440 V
Nombre de pôles 4
Courant de défaut nominal 300 A
Type de courant de fuite B
Protection sélective Yes
Pouvoir de coupure en court-circuit (Icw) 10 kA
Pouvoir de surtension 3 kA
Degré de pollution 3
Largeur en nombre d'espacements modulaires 4
Déclenchement temporisé à court terme No
Antidéflagrant No
Fréquence 50/60 Hz
Degré de protection (IP) IP20
Section du conducteur raccordable à âme pleine 1.5-50 mm²
Section des conducteurs connectables multi-câblés 1.5-35 mm²
Avec dispositif de verrouillage Yes
Température ambiante pendant le fonctionnement -25-40 °C
Équipement supplémentaire possible Yes
Tension nominale de tenue aux chocs Uimp 4 kV

Détails d’emballage

Niveau d’emballage 1 3303430167655
Niveau d’emballage 2 3303430167653

Téléchargements

Description

This product is a Acti9 RCCB-ID residual current circuit breaker (RCCB). It is a 4P circuit breaker with 125A In rated current, a sensitivity of 300mA with a B type protection class. This product protects against electrical shock by indirect contact and fire hazards. The RCCB-ID B type residual current circuit breakers provide specific protection of three phase installations and people. The Acti9 RCCB-ID ensures protection in all industrial and tertiary buildings. This product is compliant with IEC 61008, VDE 0664 and EN 61008 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1250A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The mechanical endurance is going up to 5000 cycles and electrical endurance going up to 2000 cycles. The Ue rated operational voltage is 230VAC or 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. The width in 9mm pitches is 8. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 86mm x (D) 76mm. The weight is 450g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -40°C to 85°C.