Technical Information
| État de l’article |
Nouveau |
| Nom du fabricant |
EME3P80 Eaton Distribution parts |
| Marque |
EATON
|
| Catégories |
Compteurs électriques
|
| Pays d’origine* |
IT |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Code du système harmonisé |
8537 1098 00
|
| Méthode de montage |
DRA (adaptateur pour rail DIN) |
| Largeur |
72 mm |
| Hauteur |
70 mm |
| Profondeur |
90 mm |
| Fréquence |
50 Hz |
| Courant maximal (Imax) |
6 A |
| Largeur en nombre d'espacements modulaires |
4.1 |
| Degré de protection (IP) |
IP20 |
| Taux d'impulsion |
0 Imp/kWh (kvarh) |
| Type de pôle |
Trois conducteurs |
| Tension nominale (Un) N-L |
184-276 V |
| Courant nominal (In) |
80 A |
Détails d’emballage
| Niveau d’emballage 1 |
4015081639083 |
Autres données techniques
| Modèle |
Mesure directe |
| Convient pour |
Achat/fourniture |
| Type d'indication |
Numérique |
| Nombre total de positions (compteur) |
8 |
| Type de compteur |
Electromécanique |
| Type d'interface |
Autre |
| Type d'énergie |
Puissance effective et puissance aveugle |
| Type de tarif |
Deux tarifs |
| Contrôle des tarifs |
Interne |
| Mécanisme d'échappement |
No |
| Calibré |
No |
| Approbation |
Directive sur les instruments de mesure |
| Sortie d'impulsion |
Électrique |
| Type d'impulsion |
S0 |
| Classe de précision |
B |
| Type de mesure profil de charge |
No |
| Signature EEC40 |
No |
| Avec code de verrouillage |
Yes |
| Tension nominale (Un) L-L |
319-480 V |
Description
Real and reactive power meter for three-phase alternating current with digital counter, displays up to 8 numbers (2 decimals). With 2 S0 interfaces for real/reactive power and 2 tariffs (MID device: real power display only), green backlit LCD display, for direct connection up to 80 A or for current transformer connection with a current of .../5 A, for primary current transformer current of 5 A to 10,000/5 A . Specified in 5 A increments, display with 8 numbers for showing 8 power registers, wrong connection signal (phase mix-up), accuracy class 1 for real power and power as per EN 50470-3 (B), accuracy class 2 for reactive power and power as per EN 62053-23, perfect operating current range (Ist ... Imax), for direct connection 80 A = 0.015 ... 80 A, for direct connection CT .../5 A = 0.003 ... 5 A, standard version with communications-capable add-on of 1 space units, bus transmission, power register can be set to zero (not on MID type), power register for input and output, displays instantaneous real or reactive power, sealable terminal covers