Powerline actuator 1 channel with sensor input 230V
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 31.12.25
Délai de livraison estimé à notre entrepôt (environ):
2-4 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
Powerline actuator 1 channel with sensor input 230V |
Marque |
ELTAKO
|
Catégories |
Bus System Devices (KNX/Modbus)
|
Pays d’origine |
CN |
Code du système harmonisé |
8526 9200 00
|
Système de bus KNX |
No |
Avec connexion de bus |
Yes |
Système de bus LON |
No |
Système de bus KNX radio |
No |
Fréquence radio bidirectionnelle |
No |
Détails d’emballage
Niveau d’emballage 1 |
4010312316665, 4010312316665 |
Niveau d’emballage 2 |
4010312316665 |
Niveau d’emballage 3 |
4010312316665 |
Autres données techniques
Méthode de montage |
Montage encastré (plâtre) |
Courant nominal |
10 A |
Puissance de sortie |
2000 W |
Tension nominale de fonctionnement |
230 V |
Système de bus radio fréquent |
No |
Système de bus Powernet |
Yes |
Puissance de commutation max. |
2000 W |
Nombre max. de contacts de commutation |
1 |
Courant de commutation max. |
10 A |
Autres systèmes de bus |
Aucun |
Adapté à la charge C |
Yes |
Possibilité de connecter différentes phases |
No |
Opération locale/opération manuelle |
Yes |
Avec indication LED |
Yes |
Possibilité d'extension modulaire |
No |
Module de bus détachable |
No |
Profondeur minimale de la boîte d'encastrement |
25 mm |
Puissance de commutation max. |
400 W |
Téléchargements
Description
Powerline actuator with 1 channel with sensor input. 53x43mm, 25mm deep, for mounting in 58mm switch boxes. Used as impulse switch or relay. 1 NO contact not potential free 10A/250V AC, incandescent lamps 2000 watts. Sensor input 230V. Standby loss only 0,5 watt. To control and switch at the same place. Two rotary switches are located on the front for address assignment: The left rotary switch defines the group address g with 16 alphabetical values from A to P. The right rotary switch defines the element address e with 16 numerical values from 0 to 15. Above it is a slide switch which acts as a configuration switch with positions 0, 1 and 2. Position 0: Sensor input functions as pushbutton (impulse switch). Position 1: Sensor input functions as NO contact (relay). Position 2: A change-over switch is evaluated as a pushbutton. All entries and configurations can also be accessed via the mains using the PC software SIENNA Professional. This means that another configuration can also be set that is not available via the rotary switches: Position 3: Sensor input acts as NO contact (relay inverse). To the left of the rotary switches is a red LED which indicates all activities. Next to it is a reset pushbutton and to the right of that is a service pin. For functions, please refer to the operating instructions. The terminals located above are plug-in terminals for conductor cross-sections of 0.2mm² to 1.5mm².