MS132-0.4T Circuit Breaker for Primary Transformer Protection 0.25 ... 0.40 A image 1
MS132-0.4T Circuit Breaker for Primary Transformer Protection 0.25 ... 0.40 A image 2
MS132-0.4T Circuit Breaker for Primary Transformer Protection 0.25 ... 0.40 A image 3
MS132-0.4T Circuit Breaker for Primary Transformer Protection 0.25 ... 0.40 A thumbnail 1
MS132-0.4T Circuit Breaker for Primary Transformer Protection 0.25 ... 0.40 A thumbnail 2
MS132-0.4T Circuit Breaker for Primary Transformer Protection 0.25 ... 0.40 A thumbnail 3

MS132-0.25T Circuit Breaker for Primary Transformer Protection

En stock: Non Stock fournisseur: Oui Quantité minimale de commande: 1
Prix (hors TVA):
31,622 € par pièce
Ce prix est valable jusqu’au 31.12.30
EAN: 4013614484933
MPN: 1SAM340000R1003
Colis: 1
Boîte: 40
Palette: 1280
Délai de livraison estimé à notre entrepôt (environ): Sur demande

Technical Information

État de l’article Nouveau
Nom du fabricant MS132-0.4T Circuit Breaker for Primary Transformer Protection 0.25 ... 0.40 A
Marque ABB
Catégories Breakers
Code du système harmonisé 8536 2010 00
Courant permanent nominal Iu 0.4 A
Avec déclencheur de sous-tension intégré No
Nombre de pôles 3
Réglage du courant de déclenchement de la surcharge 0.25-0.4 A
Degré de protection (IP) IP20
Type de connexion électrique du circuit principal Raccordement à vis
Type d'élément de commande Bouton tournant
Plage de réglage du déclenchement non temporisé en cas de court-circuit 8 A
Construction de l'appareil Dispositif complet dans le boîtier

Détails d’emballage

Niveau d’emballage 1 4013614484933
Niveau d’emballage 2 4013614487132
Niveau d’emballage 3 4013614484933

Téléchargements

Description

The circuit breaker for transformer protection MS132-0.4T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 0.4 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks and terminal spacers are available as accessory.