Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 1
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 2
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 3
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 4
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 5
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 6
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 7
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 8
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 9
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 10
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 11
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 12
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals image 13
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 1
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 2
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 3
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 4
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 5
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 6
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 7
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 8
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 9
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 10
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 11
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 12
Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals thumbnail 13

Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals

Commande uniquement
Prix (hors TVA):
73,24 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4015082951610
MPN: EP-400133
Colis: 1
Boîte: 32
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant Motor-protective circuit-breaker, 7.5 kW, 10 - 16 A, Feed-side screw terminals/output-side push-in terminals
Marque EATON
Catégories Disjoncteurs de protection moteur
Pays d’origine* DE
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Code du système harmonisé 8536 2010 00
Courant permanent nominal Iu 16 A
Nombre de pôles 3
Tension nominale de fonctionnement 690 V
Réglage du courant de déclenchement de la surcharge 16 A
Degré de protection (IP) IP20
Pouvoir de coupure nominale en cas de court-circuit lcu à 400 V, AC 50 kA
Plage de réglage du déclenchement non temporisé en cas de court-circuit 248 A

Détails d’emballage

Niveau d’emballage 1 4015082951610
Niveau d’emballage 2 4015080892991

Autres données techniques

Largeur 45 mm
Hauteur 93 mm
Profondeur 77 mm
Puissance nominale de fonctionnement à AC-3, 400 V 7.5 kW
Avec interrupteur auxiliaire intégré No
Avec déclencheur de sous-tension intégré No
Avec protection thermique No
Type de connexion électrique du circuit principal Raccordement à vis/à ressort
Type d'élément de commande Bouton tournant
Technique de coupure Thermomagnétique
Puissance nominale de fonctionnement à AC-3, 230 V 4 kW
Sensible aux défaillances de phase Yes
Construction de l'appareil Dispositif à encastrer technique d'encastrement fixe

Description