Analogue settable multifunction time relay, 1 NO contact 16A
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 24.12.25
Délai de livraison estimé à notre entrepôt (environ):
4-6 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
Analogue settable multifunction time relay, 1 NO contact 16A |
Marque |
ELTAKO
|
Catégories |
Push Buttons and Control
|
Pays d’origine |
CN |
Code du système harmonisé |
8536 4900 00
|
Méthode de montage |
Rail DIN |
Fonction |
Multifonction |
Type d'excitation |
Analogique avec fonction multiple |
Largeur en nombre d'espacements modulaires |
1 |
Nombre d'inverseurs |
0 |
Type de tension d'alimentation |
AC |
Tension d'alimentation |
250 V |
Unité du 1er intervalle |
Minutes/heures |
1er intervalle |
0.1-40 |
Courant nominal de commutation à 250 V AC |
16 A |
Capacité de commutation lampes à incandescence |
2300 W |
Capacité de commutation lampe fluorescente inductive |
1000 VA |
Nombre de contacts comme contact normalement fermé |
0 |
Nombre de contacts comme contact normalement ouvert |
1 |
Détails d’emballage
Niveau d’emballage 1 |
4010312602935, 4010312602935 |
Niveau d’emballage 2 |
4010312602935 |
Niveau d’emballage 3 |
4010312602935 |
Autres données techniques
Hauteur d'encastrement |
58 mm |
Tension de contrôle 1 |
230 V |
Tension de commande 2 |
8-230 V |
Type de tension de commande 1 |
AC |
Type de tension de commande 2 |
AC/DC |
Tension de contrôle de la fréquence 1 |
50 Hz |
Tension de commande de fréquence 2 |
50 Hz |
Capacité de commutation lampe fluorescente DUO |
1000 VA |
Capacité de commutation lampe fluorescente parallèle |
500 VA |
Téléchargements
Description
1 NO contact not potential free 16A/250V AC. 230V LED lamps up to 200W, incandescent lamps 2300W*. Standby loss 0.5 watt only. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Zero passage switching to protect contacts and lamps. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. 230V control voltage and additionally 8 to 230V UC electrically isolated universal control voltage. 230V supply voltage and switching voltage. Very low switching noise. Time settings between 0.1 seconds and 40 hours. Functions F: RV = release delay. AV = operate delay. TI = clock generator starting with impulse. TP = clock generator starting with pause. IA = impulse-controlled operate delay. EW = fleeting NO contact. AW = fleeting NC contact. ARV = operate and release delay. ON = permanent ON. OFF = permanent OFF. The LED below the upper function rotary switch informs about the position of the contact during the countdown. It blinks while the contact is open and stays on as long as the contact is closed. The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 second, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the time base by the multiplier. The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10). * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.