Technical Information
| État de l’article |
Nouveau |
| Nom du fabricant |
Analogue settable multifunction time relay, 1 NO contact 10A |
| Marque |
ELTAKO
|
| Catégories |
Marking Plates and Enclosures
|
| Pays d’origine* |
CN |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Code du système harmonisé |
8536 5080 00
|
| Méthode de montage |
Rail DIN |
| Fonction |
Multifonction |
| Type d'excitation |
Analogique avec fonction multiple |
| Largeur en nombre d'espacements modulaires |
1 |
| Nombre d'inverseurs |
0 |
| Type de tension d'alimentation |
AC |
| Tension d'alimentation |
230 V |
| Unité du 1er intervalle |
Minutes/heures |
| 1er intervalle |
0.1-40 |
| Courant nominal de commutation à 250 V AC |
10 A |
| Capacité de commutation lampes à incandescence |
1000 W |
| Capacité de commutation lampe fluorescente inductive |
500 VA |
| Nombre de contacts comme contact normalement fermé |
0 |
| Nombre de contacts comme contact normalement ouvert |
1 |
Détails d’emballage
| Niveau d’emballage 1 |
4010312603147, 4010312603147 |
| Niveau d’emballage 2 |
4010312603147 |
| Niveau d’emballage 3 |
4010312603147 |
Autres données techniques
| Hauteur d'encastrement |
58 mm |
| Tension de contrôle 1 |
230 V |
| Type de tension de commande 1 |
AC |
| Tension de contrôle de la fréquence 1 |
50 Hz |
| Capacité de commutation lampe fluorescente DUO |
500 VA |
| Capacité de commutation lampe fluorescente parallèle |
250 VA |
Téléchargements
Description
1 NO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 1000W*. Standby loss 0.4 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Control voltage 230V. Supply voltage same as control voltage. Time setting between 0.1 second and 40 hours. Functions F: RV = off delay. AV = operate delay. TI = clock generator starting with impulse. TP = clock generator starting with pause. IA = impulse controlled operate delay (e.g. automatic door opener). EW = fleeting NO contact. AW = fleeting NC contact. ARV = operate and release delay. ON = permanent ON. OFF = permanent OFF. The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact is open, and is continuously ON as long as the relay contact is closed. The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier. The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10). * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.