Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 1
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 2
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 3
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 4
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 5
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 6
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 7
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 8
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 9
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 10
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 11
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 12
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 13
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 14
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 15
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 16
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in image 17
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 1
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 2
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 3
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 4
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 5
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 6
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 7
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 8
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 9
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 10
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 11
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 12
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 13
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 14
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 15
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 16
I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in thumbnail 17

I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
102,22 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4015081940950
MPN: 197517
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant I/O expansion for easyE4 with temperature detection Pt100, Pt1000 or Ni1000, 24 VDC, analog inputs: 4, push-in
Marque EATON
Catégories Programmable logic controllers
Pays d’origine EE
Code du système harmonisé 8537 1091 00
Largeur 36 mm
Hauteur 90 mm
Profondeur 58 mm
Extensible No
Courant de commutation 0.5 A
Avec horloge programmable No
Avec écran No
Adapté aux fonctions de sécurité No
Nombre d'entrées numériques 0
Nombre de sorties numériques 0
Nombre d'entrées analogiques 4
Nombre de sorties analogiques 0
Type de tension d'alimentation DC
Protocole de support pour LON No
Nombre d'interfaces HW Ethernet industriel 0
Nombre d'interfaces HW RS-232 0
Nombre d'interfaces HW RS-422 0
Nombre d'interfaces HW RS-485 0
Nombre d'interfaces HW TTY série 0
Nombre d'interfaces HW USB 0
Nombre d'interfaces HW parallèles 0
Nombre d'interfaces HW autres 0
Avec interface optique No
Protocole de support pour TCP/IP No
Protocole de support pour ASI No
Protocole de support pour PROFIBUS No
Protocole de support pour CAN No
Protocole de support pour INTERBUS No
Protocole de support pour KNX No
Protocole de support pour Modbus Yes
Protocole de support pour Data-Highway No
Protocole de support pour DeviceNet No
Protocole de support pour SUCONET No
Protocole de support pour d'autres systèmes de bus No
Redondance No
Avec sortie relais No
Possibilité de montage sur rail Yes
Catégorie de sécurité antidéflagrante pour le gaz Aucun
Catégorie de sécurité antidéflagrante pour les poussières Aucun
Agent d'exploitation auxiliaire (Ex ia) No
Agent d'exploitation auxiliaire (Ex ib) No
Degré de protection (IP) IP20
Protocole de support pour SERCOS No
Protocole de support pour INTERBUS-Safety No
Nombre d'interfaces PROFINET 0
Nombre d'interfaces HW Sans fil 0
Possibilité d'encastrement frontal No
Montage en rack possible No
Montage mural/montage direct No
Dispositif d'extension No
Norme radio Bluetooth No
Norme radio Wi-Fi 802.11 No
Appareil de base No
Maître de liaison IO No
Niveau de performance selon EN ISO 13849-1 Aucun
Protocole de support pour AS-Interface Safety at Work No
Protocole de support pour DeviceNet Safety No
Protocole de support pour EtherNet/IP No
Protocole de support pour Foundation Fieldbus No
Protocole de support pour PROFINET CBA No
Protocole de support pour PROFINET IO No
Protocole de support pour PROFIsafe No
Protocole de support pour SafetyBUS p No
Tension d'alimentation AC 50 Hz 0 V
Tension d'alimentation AC 60 Hz 0 V
Tension d'alimentation DC 20.4-28.8 V
Norme radio GPRS No
Norme radio GSM No
Norme radio UMTS No
SIL selon IEC 61508 Aucun

Détails d’emballage

Niveau d’emballage 1 4015081940950

Description

I/O expansion for control relays in the easyE4 series with a rated operating voltage of 24 VDC. This expansion provides 4 analog inputs that can be used for the Pt100, Pt1000 or Ni1000 resistance temperature detectors. The Pt100, Pt1000 or Ni1000 inputs are suitable for two- and three-wire connections. Connections are established using push-in terminals. The connection to the control relay or any other expansion in the easyE4 series is established using the EASY-E4-CONNECT1 connector (item 197225), which is included as standard.

Remplacement

Accessoire

Accessoire

Remplacement
4015081940844 4015081940851 4015081940868 4015081940875
Accessoire
4015081940844 4015081940851 4015081940868 4015081940875
Accessoire
4015081940844 4015081940851 4015081940875 4015081940868