RS485 bus wireless single-phase energy meter transmitter module 65A image 1

RS485 bus wireless single-phase energy meter transmitter module 65A

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
68,08 €
Ce prix est valable jusqu’au 31.12.25
EAN: 4010312501511
MPN: 30014050
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 2-4 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant RS485 bus wireless single-phase energy meter transmitter module 65A
Marque ELTAKO
Catégories Sensors
Pays d’origine CN
Code du système harmonisé 9028 3011 00
Modèle Compteur d'énergie
Type de connexion Direct
Système de bus KNX No
Système de bus radio fréquent Yes
Système de bus Powernet No
Commutateur de tarif No
Interface d'impulsion S0 Aucun
Puissance réactive -
Classe de précision 1
Approuvé selon PTB No
Autres systèmes de bus Aucun
Système de bus LON No
Système de bus KNX radio No
Fréquence radio bidirectionnelle No

Détails d’emballage

Niveau d’emballage 1 4010312501511, 4010312501511
Niveau d’emballage 2 4010312501511
Niveau d’emballage 3 4010312501511

Téléchargements

Description

Wireless single-phase energy meter transmitter module, maximum current 65A. Only 0.5 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Accuracy class B (1%). With RS485 interface. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. The meter reading, the current power and the serial number will be handed over to the bus – eg for forwarding to an external computer, an Professional Smart Home controller – and also to the wireless network via FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the manual. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power is not metered. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1 phase conductor with a max. current up to 65A can be connected. The inrush current is 40mA. In operation the rotary switch must be set to AUTO. Power consumption is indicated using a LED. If the L input and the L output were interchanged when hooked up, a normal rate (HT)/off-peak (NT) switch­over telegram is transmitted to indicate the hook-up error. If the anticipated load exceeds 50%, maintain an air gap of ½ pitch unit to the devices mounted adjacently. Thereto included are 2 spacers DS14, a short jumper and two long jumpers.