Technical Information
| État de l’article |
Nouveau |
| Nom du fabricant |
Wireless single-phase energy meter |
| Marque |
ELTAKO
|
| Catégories |
Bus System Devices (KNX/Modbus)
|
| Pays d’origine* |
CN |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Code du système harmonisé |
8526 9200 00
|
| Modèle |
Autre |
| Type de connexion |
Direct |
| Interface d'impulsion S0 |
Aucun |
| Classe de précision |
1 |
Détails d’emballage
| Niveau d’emballage 1 |
4010312311059, 4010312311059 |
| Niveau d’emballage 2 |
4010312311059 |
| Niveau d’emballage 3 |
4010312311059 |
Autres données techniques
| Système de bus KNX |
No |
| Système de bus radio fréquent |
Yes |
| Système de bus Powernet |
No |
| Commutateur de tarif |
No |
| Puissance réactive |
No |
| Approuvé selon PTB |
No |
| Autres systèmes de bus |
Aucun |
| Système de bus LON |
No |
| Système de bus KNX radio |
No |
| Fréquence radio bidirectionnelle |
No |
Téléchargements
Description
Wireless single-phase energy meter, maximum current 65A. Only 0.5 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. This single-phase energy meter measures active energy by means of the current between input and output and transmits the current power and meter reading over the Eltako wireless network. Accuracy class B (1%). Evaluation and smart link via Smart Home-Controller. The internal power consumption of max. 0.5 watt active power is not metered. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1 phase conductor with a max. current up to 65A can be connected. If the anticipated load exceeds 50%, maintain an air gap of ½ pitch unit to the devices mounted adjacently. If necessary, use spacer DS12. The inrush current is 40mA. The consumption is saved to a non-volatile memory and is immediately available again after a power failure. Wireless telegrams: A telegram is transmitted within 60 seconds if the power status changes by min. 10 percent. A change in meter reading is transmitted immediately. A full telegram comprising meter reading and power status is transmitted every 10 minutes. When the power supply is switched on, a teach-in telegram is sent to teach in the associated energy consumption indicator. If the L input and the L output were interchanged when hooked up, a normal rate (HT)/off-peak (NT) switchover telegram is transmitted to indicate the hook-up error.