Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 1
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 2
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 3
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 4
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 5
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 6
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 7
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres image 8
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 1
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 2
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 3
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 4
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 5
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 6
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 7
Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres thumbnail 8

Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 3
Prix (hors TVA):
156,45 €
Ce prix est valable jusqu’au 24.12.25
Sous-total: 469,35 € MOQ: 3
EAN: 5027590456043
MPN: 170M5168
Colis: 1
Boîte: 3
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, 110 mm centres
Marque EATON
Catégories Fuses
Pays d’origine HU
Code du système harmonisé 8536 1090 00
Type de courant AC
Courant nominal 1250 A
Code couleur Aucun
Catégorie d'utilisation aR (protection des semi-conducteurs accompagnés)
Type d'indicateur d'état du fusible Indicateur d'état du fusible supérieur
Pouvoir de coupure 200 kA
Tension nominale AC 600 V
Perte de puissance au courant nominal 130 W
Type de fusible selon IEC 60269 2
Distance centre à centre des connexions 108 mm
Trous de fixation Autre

Détails d’emballage

Niveau d’emballage 1 5027590456043
Niveau d’emballage 2 5996516014868

Description

Fuse, Fuse-link, high speed, 1250 A, AC 600 V, DIN 2, 61 x 61 x 108 mm, aR, DIN, IEC, single indicator, square body with centre-bolted tags (slotted), semiconductor protection, DIN 43653, IEC 60269-4, Breaking Capacity 200 kA

Remplacement

Accessoire

Suivi

Accessoire

Suivi