Technical Information
| État de l’article |
Nouveau |
| Nom du fabricant |
Switching power supply unit 12V/12W |
| Marque |
ELTAKO
|
| Catégories |
AC/DC Power Supply Units
|
| Pays d’origine* |
CN |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Code du système harmonisé |
8504 3180 00
|
| Largeur |
18 mm |
| Hauteur |
58 mm |
| Profondeur |
58 mm |
| Type de tension d'alimentation |
AC |
| Puissance de sortie |
12 W |
| Possibilité de montage sur rail |
Yes |
| Possibilité de montage mural |
No |
| 1ère tension de sortie secondaire |
12 V |
| Tension d'alimentation nominale à AC 50 Hz |
230 V |
| Courant de sortie max. 1 |
1 A |
Détails d’emballage
| Niveau d’emballage 1 |
4010312315095, 4010312315095 |
| Niveau d’emballage 2 |
4010312315095 |
| Niveau d’emballage 3 |
4010312315095 |
Autres données techniques
| Largeur encastrée |
18 mm |
| Version modulaire |
Yes |
| Adapté aux fonctions de sécurité |
No |
| Largeur en nombre d'espacements modulaires |
1 |
| Tension de sortie stabilisée |
Yes |
| Type de connexion électrique |
Raccordement à vis |
| Stabilisé |
Yes |
| Degré de protection (IP) |
IP20 |
| Montage direct possible |
No |
| Tension secondaire réglable |
No |
| Protection contre les courts-circuits |
Yes |
| Valeur nominale de la tension de sortie 1 |
12 V |
Téléchargements
Description
Switching power supply unit rated capacity 12W. Standby loss 0.2 watt only. Modular devices for DIN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. If the total power demand of a Series 14 bus system is higher than 8W, other switching power supply units FSNT14-12V/12W are required. These are each supplying a group of actuators, which are separated with a disconnecting link on the FSNT14. The scope of delivery includes 1 disconnecting link TB14 1 module, 1 jumper 1.5 modules and a spacer DS14. At a load of more than 50% of the rated capacity and always if there are adjacent switching power supply units and dimmers a ventilation clearance of 1/2 module must be maintained with the spacers DS14. Therefore, this and a long jumper are included to the dimmers. Input voltage 230V (-20% bis +10%). Efficiency 83%. Stabilised output voltage ±1%, low residual ripple. Short-circuit proof. Overload protection and over-temperature switch-off by means of swichting off with automatic switching-on after fault clearance (autorecovery function). This switching power supply unit can also be used for producing a redundancy. Therefore only 1 FSNT14 should be plugged in parallel to the integrated power supply units into the FAM14 and FTS14KS and connected to a normal jumper. For an optimal load distribution, the FSNT14 should be placed as close as possible next to the last bus actuator.