Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
Self-learning mains disconnection relay, 1 NO contact 10A image 1

Self-learning mains disconnection relay, 1 NO contact 10A

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
46,03 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4010312203477
MPN: 61100530
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant Self-learning mains disconnection relay, 1 NO contact 10A
Marque ELTAKO
Catégories Relays
Pays d’origine CN
Code du système harmonisé 8536 5080 00
Méthode de montage Autre
Profondeur d'encastrement 26 mm
Courant nominal 10 A
Tension nominale 250 V
Fréquence nominale 50 Hz
Largeur en nombre d'espacements modulaires 0
Courant du seuil d'enclenchement 20 mA
Courant de commutation maximal (cos phi = 0,6) 10 A
Charge max. lampe à incandescence 1000 W
Charge max. lampe fluorescente 1000 VA
Charge max. lampe fluorescente (circuit Duo) 1000 VA
Charge maximale lampe fluorescente (parallèle compensée) 500 VA
Degré de protection (IP) IP20
Tension de surveillance DC

Détails d’emballage

Niveau d’emballage 1 4010312203477, 4010312203477
Niveau d’emballage 2 4010312203477
Niveau d’emballage 3 4010312203477

Téléchargements

Description

1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 1000W. Standby loss 0.8 watt only. Built-in device for installation. 45mm long, 45mm wide, 26mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit. It is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection relay connects the phase. If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB.