Self-learning mains disconnection relay, 1 NO contact 16A image 1

Self-learning mains disconnection relay, 1 NO contact 16A

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
50,35 €
Ce prix est valable jusqu’au 31.12.25
EAN: 4010312203255
MPN: 22100231
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 2-4 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant Self-learning mains disconnection relay, 1 NO contact 16A
Marque ELTAKO
Catégories Relays
Pays d’origine CN
Code du système harmonisé 8536 5080 00
Méthode de montage Rail DIN
Profondeur d'encastrement 26 mm
Courant nominal 10 A
Tension nominale 230 V
Fréquence nominale 50 Hz
Largeur en nombre d'espacements modulaires 3
Courant du seuil d'enclenchement 20 mA
Courant de commutation maximal (cos phi = 0,6) 16 A
Charge max. lampe à incandescence 2300 W
Charge max. lampe fluorescente 500 VA
Charge max. lampe fluorescente (circuit Duo) 1000 VA
Charge maximale lampe fluorescente (parallèle compensée) 500 VA
Degré de protection (IP) IP20
Tension de surveillance DC

Détails d’emballage

Niveau d’emballage 1 4010312203255, 4010312203255
Niveau d’emballage 2 4010312203255
Niveau d’emballage 3 4010312203255

Téléchargements

Description

1 NO contact not potential free 16A/250V AC. Self-learning. 230V LED lamps up to 200W, incandescent lamp load 2300W. Standby loss 0.8 watt only. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide and 58mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR12-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 200mA, are acceptable and, once major loads are disconnected, they do not prevent field disconnection. The limit is taught-in automatically by the FR12 using a patented method so you need not set the limit manually. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection switch connects the monitored phase after approx. 1 sec and the LED lights red.