RS485 bus actuator multifunction impulse switch with iIntegrated relay function
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 31.12.25
Délai de livraison estimé à notre entrepôt (environ):
2-4 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
RS485 bus actuator multifunction impulse switch with iIntegrated relay function |
Marque |
ELTAKO
|
Catégories |
Bus System Devices (KNX/Modbus)
|
Pays d’origine |
CN |
Code du système harmonisé |
8526 9200 00
|
Système de bus KNX |
No |
Avec connexion de bus |
Yes |
Système de bus LON |
No |
Système de bus KNX radio |
No |
Fréquence radio bidirectionnelle |
Yes |
Détails d’emballage
Niveau d’emballage 1 |
4010312313725, 4010312313725 |
Niveau d’emballage 2 |
4010312313725 |
Niveau d’emballage 3 |
4010312313725 |
Autres données techniques
Méthode de montage |
DRA (adaptateur pour rail DIN) |
Courant nominal |
16 A |
Puissance de sortie |
2000 W |
Tension nominale de fonctionnement |
12 V |
Système de bus radio fréquent |
Yes |
Système de bus Powernet |
No |
Puissance de commutation max. |
2000 W |
Nombre max. de contacts de commutation |
1 |
Largeur en nombre d'espacements modulaires |
1 |
Courant de commutation max. |
16 A |
Autres systèmes de bus |
Aucun |
Adapté à la charge C |
No |
Possibilité de connecter différentes phases |
No |
Opération locale/opération manuelle |
No |
Degré de protection (IP) |
IP20 |
Avec indication LED |
No |
Possibilité d'extension modulaire |
No |
Module de bus détachable |
Yes |
Puissance de commutation max. |
400 W |
Téléchargements
Description
Multifunction impulse switch with integrated relay function, 1+1 NO potential free 16A/250V AC, 230V LED lamps up to 400W, incandescent lamps 2000W, with DX technology. Bidirectional. Only 0.1-0.6 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Patented Eltako Duplex technology allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional standby consumption of only 0.1 watt. Maximum current over both contacts 16A for 230V. If supply voltage fails, the device is switched off in defined mode. When both relays of the FMS14 are switched on, 0.6 watt are required. The upper and the middle rotary switches are for teaching-in the sensors. In normal mode, the middle rotary switch is then set to AUTO and the bottom rotary switch to the required function: 2S = Impulse switch with 2 NO contacts. (2xS) = 2-way impulse switch each with one NO relay. WS = Impulse switch with 1 NO contact and 1 NC contact (0.3 watt standby loss). SS1 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 1. SS2 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 2. SS3 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 3. GS = Impulse group switch 1+1 NO contacts. 2R = Switching relay with 2 NO contacts. WR = Switching relay with 1 NO contact and 1 NC contact (0.3 watt standby loss). RR = Switching relay (closed-circuit current relay) with 2 NC contacts (0.5 watt standby loss). GR = Group relay 1+1 NO contacts. Switching sequence SS1: 0 - contact 1 (K-1) - contact 2 (K-2) - contact 1 + 2. Switching sequence SS2: 0 - contact 1 - contact 1 + 2 - contact 2. Switching sequence SS3: