RS485 bus actuator 4-channel heating/cooling relay image 1

RS485 bus actuator 4-channel heating/cooling relay

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
52,16 €
Ce prix est valable jusqu’au 31.12.25
EAN: 4010312314982
MPN: 30014010
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 2-4 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant RS485 bus actuator 4-channel heating/cooling relay
Marque ELTAKO
Catégories Sensors
Pays d’origine CN
Code du système harmonisé 8526 9200 00
Méthode de montage DRA (adaptateur pour rail DIN)
Nombre de sorties 4
Courant de sortie max. 4 A
Courant de commutation maximal (charge résistive) 4 A
Système de bus KNX No
Système de bus radio fréquent Yes
Système de bus Powernet No
Avec connexion de bus Yes
Largeur en nombre d'espacements modulaires 1
Autres systèmes de bus Aucun
Système de bus LON No
Tension de commutation 230 V
Degré de protection (IP) IP20
Variable de correction cohérente Yes
Correction de la variable de commutation Yes
Fonction de protection des vannes No
Commutateur manuel Yes
Système de bus KNX radio No
Fréquence radio bidirectionnelle Yes
Module de bus détachable Yes

Détails d’emballage

Niveau d’emballage 1 4010312314982, 4010312314982
Niveau d’emballage 2 4010312314982
Niveau d’emballage 3 4010312314982

Téléchargements

Description

"Heating/cooling relay with 4 channels, 1 NO contact per channel 4A/250V AC, potential free from the power supply, with DX technology. Bidirectional. Only 0.1 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Patented Eltako Duplex technology allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional standby consumption of only 0.1 watt. When all 4 relays are switched on, a power of 0.7 watts is required. If supply voltage fails, the device is switched off in defined mode. This heating/cooling relay assesses information about wireless temperature controllers or sensors. Possibly supplemented by window/door contacts, motion detectors, window handle sensor FFG7B-rw and wireless pushbuttons. As an alternative to a wireless temperature controller, the temperature information on the set and actual values can be obtained from a Professional Smart Home controller. It is also possible to specify the set temperature via the Professional Smart Home controller and thus limiting the setting range of the wireless temperature controller. Top rotary switch for adjustable hysteresis: Left stop: lowest hysteresis 0.5º. Middle position: hysteresis 2.5º. Right stop: largest hysteresis 4.5º. Inbetween, divisions in steps of 0.5º. Middle rotary switch for regulation types: AUTO 1: With PWM control at T = 4 minutes. (PWM = pulse width modulation). (suitable for valves with thermoelectric valve drive). AUTO 2: With PWM control at T = 15 minutes. (suitable for valves with motor-driven valve drive). AUTO 3: With 2-point control. Bottom rotary switch for operating modes: H: heating mode (Contacts 1 to 4). K: cooling mode (Contacts 1 to 4). HK: heating mode (Contact 3 and 4) and cooling mode (Contact 1 and 2). In heating mode, the frost protection function is always enabled. As soon as the actual temperature drops below 8°C, the temperature is controlled in the selected operating mode to 8°C. If one or several windows are open, the output remains off provided the window/door contacts FTK or window handle sensors FFG7B-rw are taught-in. In heating mode, however, the frost protection remains enabled. As long as all taught-in motion detectors FBH detect no motion, the device is switched to set­back mode. In heating mode, the reference temperature is set back by 2°