Multifunction impulse switch with integrated relay function, 1 + 1 NO contacts 10A
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 24.12.25
Délai de livraison estimé à notre entrepôt (environ):
4-6 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
Multifunction impulse switch with integrated relay function, 1 + 1 NO contacts 10A |
Marque |
ELTAKO
|
Catégories |
Relais
|
Pays d’origine |
CN |
Code du système harmonisé |
8536 5080 00
|
Méthode de montage |
Montage encastré (plâtre) |
Fonction |
Autre |
Tension de contrôle 1 |
8-230 V |
Type de tension de commande 1 |
AC |
Type de tension d'alimentation |
AC/DC |
Tension d'alimentation |
230 V |
Courant nominal de commutation |
16 A |
Nombre de contacts comme contact normalement ouvert |
2 |
Détails d’emballage
Niveau d’emballage 1 |
4010312108079, 4010312108079 |
Niveau d’emballage 2 |
4010312108079 |
Niveau d’emballage 3 |
4010312108079 |
Autres données techniques
Profondeur d'encastrement |
58 mm |
Tension de commande 2 |
10-230 V |
Type de tension de commande 2 |
DC |
Tension de contrôle de la fréquence 1 |
50 Hz |
Tension de commande de fréquence 2 |
50 Hz |
Adapté au fonctionnement manuel |
No |
Courant de commutation maximal (cos phi = 0,6) |
8 A |
Charge max. lampe à incandescence |
2000 W |
Charge max. lampe fluorescente |
1000 VA |
Charge max. lampe fluorescente (circuit Duo) |
1000 VA |
Charge maximale lampe fluorescente (parallèle compensée) |
500 VA |
Nombre de contacts comme contact normalement fermé |
0 |
Nombre de contacts comme contact inverseur |
0 |
Téléchargements
Description
1+1 NO contacts potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load up to 2000W. No standby loss. For installation. 45mm long, 45mm wide, 32mm deep. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. Universal control voltage 8 to 230V UC. No permanent power supply necessary, therefore no standby loss. By using bistable relays coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. The functions of the second rotary switch are preselected using the rotary switch ES/ER. The setting ER selects the function in brackets. 10 different functions are selectable. 2S = Impulse switch with 2 NO contacts. (2R) = Switching relay with 2 NO contacts. WS = Impulse switch with 1 NO contact and 1 NC contact. (WR) = Switching relay with 1 NO contact and 1 NC contact. SS1 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 0 - contact 1 (1-2) - contact 2 (3-4) - contacts 1+2. (RR) = Switching relay (closed-circuit current relay) with 2 NC contacts. SS2 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 0 - contact 1 - contacts 1+2 - contact 2. (EW) = Impulse relay for fleeting NO contact with 1 NO contact and 1 NC contact, wiping time 1 sec. GS = Impulse group switch 1+1 NO contacts for switching sequence 0 - contact 1 - 0 - contact 2. (GR) = Group relay 1+1 NO contacts (relay with alternating closing contacts). This relay is not suitable to feed back the switching voltage signal of a dimmer switch. Use only relays ESR12DDX-UC, ESR12NP-230V+UC or ESR61NP-230V+UC for this purpose. The electronics does not have an internal power supply and therefore no power is consumed in any contact position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.