Impulse switch for installation in lighting fittings, 1 NO contact 10A
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 24.12.25
Délai de livraison estimé à notre entrepôt (environ):
4-6 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
Impulse switch for installation in lighting fittings, 1 NO contact 10A |
Marque |
ELTAKO
|
Catégories |
Relais
|
Pays d’origine |
CN |
Code du système harmonisé |
8536 5080 00
|
Méthode de montage |
Autre |
Fonction |
Autre |
Tension de contrôle 1 |
12-24 V |
Type de tension de commande 1 |
AC/DC |
Type de tension d'alimentation |
AC |
Tension d'alimentation |
250 V |
Courant nominal de commutation |
10 A |
Nombre de contacts comme contact normalement ouvert |
1 |
Détails d’emballage
Niveau d’emballage 1 |
4010312101063, 4010312101063 |
Niveau d’emballage 2 |
4010312101063 |
Niveau d’emballage 3 |
4010312101063 |
Autres données techniques
Profondeur d'encastrement |
28 mm |
Largeur en nombre d'espacements modulaires |
2.22 |
Adapté au fonctionnement manuel |
No |
Charge max. lampe à incandescence |
500 W |
Charge max. lampe fluorescente (circuit Duo) |
1000 VA |
Nombre de contacts comme contact normalement fermé |
0 |
Nombre de contacts comme contact inverseur |
0 |
Téléchargements
Description
For installation in lighting fittings. 1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load up to 500W. Standby loss 1 watt only. Built-in device for installation. 85mm long, 40mm wide, 28mm deep. With integrated transformer to galvanically separate the control circuit from the switching circuit to comply with the requirements for safety extra low voltage (SELV) to EN 60669-2-2. As of production week 18/18, compliance is fulfilled with the safety requirements of 2x MOPP to EN 60601-1. Activation by internal voltage or external control voltage of 12 to 24V UC, control current 10mA at 24V. Continuous power supply 230V. A circuit breaker of max. 10A is required. Incandescent lamps and halogen lamps load up to 500W1) and fluorescent lamps with conventional ballast units in lead-lag circuit up to 1000VA. Fluorescent lamps with conventional ballast units parallel compensated 300VA. Temperatures at the mounting location between -20°C and +50°C. Min. command pulse duration/command pause 20/300ms. Connections on the low voltage side: 4-pole pin receptacle for STOCKO MKF 13264-6-0-404 plug, 230V connections: 6-pole terminal strip with plug-in terminals. max. conductor cross section 2.5mm2. One STOCKO plug comes with each device. 1) For lamps with 150W max.