Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
Earth-fault release, 30mA, 3p, bottom image 1
Earth-fault release, 30mA, 3p, bottom image 2
Earth-fault release, 30mA, 3p, bottom image 3
Earth-fault release, 30mA, 3p, bottom image 4
Earth-fault release, 30mA, 3p, bottom image 5
Earth-fault release, 30mA, 3p, bottom image 6
Earth-fault release, 30mA, 3p, bottom thumbnail 1
Earth-fault release, 30mA, 3p, bottom thumbnail 2
Earth-fault release, 30mA, 3p, bottom thumbnail 3
Earth-fault release, 30mA, 3p, bottom thumbnail 4
Earth-fault release, 30mA, 3p, bottom thumbnail 5
Earth-fault release, 30mA, 3p, bottom thumbnail 6

Earth-fault release, 30mA, 3p, bottom

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
349,06 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4015081044191
MPN: 104609
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 8-10 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant Earth-fault release, 30mA, 3p, bottom
Marque EATON
Catégories Accessories (Automatics & control)
Pays d’origine CZ
Code du système harmonisé 8538 9099 00
Délai réglable No
Courant de défaut nominal 0.03 A
Tension nominale d'alimentation de commande Us à AC 50HZ 200-415 V
Tension nominale d'alimentation Us à AC 60HZ 200-415 V
Tension nominale d'alimentation de commande Us à DC 0 V
Tension de fonctionnement nominale maximale Ue 415 V
Temps de retard à l'enclenchement de la puissance max. 30 ms

Détails d’emballage

Niveau d’emballage 1 4015081044191

Description

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: approved according to IEC/EN 60947-2 not UL/CSA approved. Suitable for use in three- and single-phase systems. Pulse current sensitive according to core-balance principle. For 3 and 4 pole NZM1(-4) circuit-breakers and switch-disconnectors N1(-4).mains voltage independent Ue = 200 .. 415 V 50/60 Hz. At I △n = 0.03 A: delay time t v always fixed setting to 10 ms. Warning message > 30 % I △n by yellow LED . Trip indication max. 2 auxiliary contacts (HIAFI) can be fitted by user: N/O = M22-K01, N/C = M22-K10 are reset via the reset button. If the trip-indicating auxiliary contact in the fault current block is used, the N/C contacts operates as a N/O contact and the N/C contact operates as an N/O contact. Double contact not permissible. Not in combination with insulated enclosure or main switch assembly kit for side panel mounting with mounting bracket. NZM1-XFI...R can not be used in combination with lower cover NZM1-XUSA.NZM1-XFI…U not in combination with shunt or undervoltage release, early-make auxiliary contacts . Rated ultimate short-circuit breaking capacity is determined by fitted NZM1, NS1. When using a switch-disconnector N1, by the back-up fuse to be used. See technical data. Can be used for: NZM1, N(S)1