Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right image 1
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right image 2
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right image 3
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right image 4
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right image 5
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right image 6
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right thumbnail 1
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right thumbnail 2
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right thumbnail 3
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right thumbnail 4
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right thumbnail 5
NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right thumbnail 6

Earth-fault release, 300mA, 4p, right

Commande uniquement
Prix (hors TVA):
283,14 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4015081044177
MPN: 104607
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant NZM1-4-XFI300R Earth-fault release, 300mA, 4p, right
Marque EATON
Catégories Trip & Release Units
Pays d’origine* CZ
* The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager.
Code du système harmonisé 8538 9099 00
Courant de défaut nominal 0.3 A
Tension nominale d'alimentation de commande Us à AC 50HZ 200-415 V
Tension nominale d'alimentation Us à AC 60HZ 200-415 V
Tension nominale d'alimentation de commande Us à DC 0 V
Tension de fonctionnement nominale maximale Ue 415 V

Détails d’emballage

Niveau d’emballage 1 4015081044177

Autres données techniques

Délai réglable No
Temps de retard à l'enclenchement de la puissance max. 300 ms

Description

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: approved according to IEC/EN 60947-2 not UL/CSA approved. Suitable for use in three- and single-phase systems. Pulse current sensitive according to core-balance principle. For 3 and 4 pole NZM1(-4) circuit-breakers and switch-disconnectors N1(-4).mains voltage independent Ue = 200 .. 415 V 50/60 Hz. At I △n = 0.03 A: delay time t v always fixed setting to 10 ms. Warning message > 30 % I △n by yellow LED . Trip indication max. 2 auxiliary contacts (HIAFI) can be fitted by user: N/O = M22-K01, N/C = M22-K10 are reset via the reset button. If the trip-indicating auxiliary contact in the fault current block is used, the N/C contacts operates as a N/O contact and the N/C contact operates as an N/O contact. Double contact not permissible. Not in combination with insulated enclosure or main switch assembly kit for side panel mounting with mounting bracket. NZM1-XFI...R can not be used in combination with lower cover NZM1-XUSA.NZM1-XFI…U not in combination with shunt or undervoltage release, early-make auxiliary contacts . Rated ultimate short-circuit breaking capacity is determined by fitted NZM1, NS1. When using a switch-disconnector N1, by the back-up fuse to be used. See technical data. Can be used for NZM1-4, N1-4