Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
CT operated three-phase energy meter, MID approval image 1

CT operated three-phase energy meter, MID approval

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
169,25 €
Ce prix est valable jusqu’au 31.12.25
EAN: 4010312501641
MPN: 28305015
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 2-4 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant CT operated three-phase energy meter, MID approval
Marque ELTAKO
Catégories Electric meters
Pays d’origine CN
Code du système harmonisé 9028 3019 00
Méthode de montage DRA (adaptateur pour rail DIN)
Largeur 70 mm
Hauteur 82 mm
Profondeur 58 mm
Fréquence 50 Hz
Courant maximal (Imax) 6 A
Largeur en nombre d'espacements modulaires 4
Degré de protection (IP) IP20
Taux d'impulsion 10 Imp/kWh (kvarh)
Type de pôle Quatre conducteurs
Tension nominale (Un) N-L 230 V
Courant nominal (In) 5 A

Détails d’emballage

Niveau d’emballage 1 4010312501641, 4010312501641
Niveau d’emballage 2 4010312501641

Autres données techniques

Modèle Transformateur de mesure
Convient pour Achat
Type d'indication Numérique
Nombre total de positions (compteur) 7
Type de compteur Électronique
Type d'interface Autre
Type d'énergie Puissance effective
Type de tarif Un tarif
Mécanisme d'échappement Yes
Calibré Yes
Approbation Directive sur les instruments de mesure
Sortie d'impulsion Optique
Type d'impulsion S0
Classe de précision B
Type de mesure profil de charge -
Signature EEC40 -
Avec code de verrouillage -
Tension nominale (Un) L-L 400 V

Téléchargements

Description

CT operated three-phase energy meter with settable CT ratio and MID. Maximum current 3x5A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. This three-phase energy meter measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 5A can be connected. The inrush current is 10mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 10 times per kWh. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy, the active energy per resettable memory, and the instantaneous values of consumption, voltage and current per phase. The CT ratio can also be set. It is set to 5:5 at the factory and blocked with a bridge over the terminals which are marked with JUMPER. To adjust the CT ratio to the installed transformer remove the bridge and reset the energy meter according to the operation manual. Then block it again with the bridge. Adjustable current transformer ratios: 5:5, 50:5, 100:5, 150:5, 200:5, 250:5, 300:5, 400:5, 500:5, 600:5, 750:5, 1000:5, 1250:5 and 1500:5. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display. Important! Before working on the current transformers disconnect the voltage paths of the energy meters.