Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
Two-way three-phase meter, MID calibrated image 1

Two-way three-phase meter, MID calibrated

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
149,44 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4010312501870
MPN: 28480315
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant Two-way three-phase meter, MID calibrated
Marque ELTAKO
Catégories Electric meters
Pays d’origine CN
Code du système harmonisé 9028 3019 00
Méthode de montage DRA (adaptateur pour rail DIN)
Largeur 70 mm
Hauteur 82 mm
Profondeur 58 mm
Fréquence 50 Hz
Courant maximal (Imax) 80 A
Largeur en nombre d'espacements modulaires 4
Degré de protection (IP) IP20
Taux d'impulsion 1000 Imp/kWh (kvarh)
Type de pôle Quatre conducteurs
Tension nominale (Un) N-L 230 V
Courant nominal (In) 10 A

Détails d’emballage

Niveau d’emballage 1 4010312501870, 4010312501870
Niveau d’emballage 2 4010312501870

Autres données techniques

Modèle Mesure directe
Convient pour Achat
Type d'indication Numérique
Nombre total de positions (compteur) 7
Type de compteur Électronique
Type d'interface Autre
Type d'énergie Puissance effective
Type de tarif Deux tarifs
Contrôle des tarifs Extérieur
Mécanisme d'échappement -
Calibré Yes
Approbation Directive sur les instruments de mesure
Sortie d'impulsion Optique
Type d'impulsion S0
Classe de précision B
Type de mesure profil de charge -
Signature EEC40 -
Avec code de verrouillage -
Tension nominale (Un) L-L 400 V

Téléchargements

Description

Two-way three-phase meter. Maximum current 3x80A. Standby loss 0.5 watt per path only. Modulair device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface as standard. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. The active energy is added depending on the sign. Positive power in the meter means energy consumption, negative power means energy delivery. The energy measurement is balanced. If the energy consumption (P positive) is greater than the energy supply (P negative), the meter reading T arrow right is increased. If the energy supply is greater than the energy consumption, the meter reading T arrow left is increased. Energy consumption is shown with a right arrow and energy supply is shown with a left arrow above the active bar in the display. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. Energy consumption and energy supply values are stored in non-volatile memory and are displayed again immediately after a power failure. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu. First the background lighting switches on. Then the total active energy per consumption and delivery, the active energy of the resettable memory consumption and delivery as well as the instantaneous power, voltage and current values for each phase conductor can be displayed. Error message: If a phase connection is missing, the corresponding phase is shown on the display.