Three-phase energy meter, without approval
En stock: Non
Stock fournisseur: Non
Quantité minimale de commande: 1
Ce prix est valable jusqu’au 24.12.25
Délai de livraison estimé à notre entrepôt (environ):
4-6 weeks
Technical Information
État de l’article |
Nouveau |
Nom du fabricant |
Three-phase energy meter, without approval |
Marque |
ELTAKO
|
Catégories |
Compteurs électriques
|
Pays d’origine |
CN |
Code du système harmonisé |
9028 3019 00
|
Méthode de montage |
DRA (adaptateur pour rail DIN) |
Largeur |
70 mm |
Hauteur |
82 mm |
Profondeur |
58 mm |
Fréquence |
50 Hz |
Courant maximal (Imax) |
80 A |
Largeur en nombre d'espacements modulaires |
4 |
Degré de protection (IP) |
IP20 |
Taux d'impulsion |
1000 Imp/kWh (kvarh) |
Type de pôle |
Quatre conducteurs |
Tension nominale (Un) N-L |
230 V |
Courant nominal (In) |
10 A |
Détails d’emballage
Niveau d’emballage 1 |
4010312501719, 4010312501719 |
Niveau d’emballage 2 |
4010312501719 |
Autres données techniques
Modèle |
Mesure directe |
Convient pour |
Achat/fourniture |
Type d'indication |
Numérique |
Nombre total de positions (compteur) |
7 |
Type de compteur |
Électronique |
Type d'interface |
Autre |
Type d'énergie |
Puissance effective |
Type de tarif |
Deux tarifs |
Mécanisme d'échappement |
Yes |
Calibré |
No |
Sortie d'impulsion |
Optique |
Type d'impulsion |
S0 |
Classe de précision |
B |
Type de mesure profil de charge |
No |
Signature EEC40 |
No |
Avec code de verrouillage |
No |
Tension nominale (Un) L-L |
400 V |
Téléchargements
Description
Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong 'false' and the corresponding phase conductor are indicated on the display.