Inscrivez-vous pour débloquer vos prix B2B exclusifs et commencez vos achats. Inscrivez-vous maintenant!
RS485 bus wireless three-phase energy meter, MID approval image 1

RS485 bus wireless three-phase energy meter, MID approval

En stock: Non Stock fournisseur: Non Quantité minimale de commande: 1
Prix (hors TVA):
158,17 €
Ce prix est valable jusqu’au 24.12.25
EAN: 4010312501733
MPN: 28365715
Colis: 1
Délai de livraison estimé à notre entrepôt (environ): 4-6 weeks

Technical Information

État de l’article Nouveau
Nom du fabricant RS485 bus wireless three-phase energy meter, MID approval
Marque ELTAKO
Catégories Electric meters
Pays d’origine CN
Code du système harmonisé 9028 3019 00
Méthode de montage DRA (adaptateur pour rail DIN)
Largeur 70 mm
Hauteur 82 mm
Profondeur 58 mm
Fréquence 50 Hz
Courant maximal (Imax) 80 A
Largeur en nombre d'espacements modulaires 4
Degré de protection (IP) IP20
Type de pôle Quatre conducteurs
Tension nominale (Un) N-L 230 V
Courant nominal (In) 10 A

Détails d’emballage

Niveau d’emballage 1 4010312501733, 4010312501733
Niveau d’emballage 2 4010312501733

Autres données techniques

Modèle Mesure directe
Convient pour Achat
Type d'indication Numérique
Nombre total de positions (compteur) 7
Type de compteur Électronique
Type d'interface RS-485
Type d'énergie Puissance effective
Type de tarif Deux tarifs
Contrôle des tarifs Extérieur
Mécanisme d'échappement Yes
Calibré Yes
Approbation Directive sur les instruments de mesure
Sortie d'impulsion Électrique
Classe de précision B
Type de mesure profil de charge -
Signature EEC40 -
Avec code de verrouillage -
Tension nominale (Un) L-L 400 V

Téléchargements

Description

RS485 bus wireless three-phase energy meter. Maximum current 3x80A. Standby loss 0.8W at L1 and only 0.5W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With RS485 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.8W or 0.5W active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The terminals ‹L1 and N must always be connected. Connection to the Eltako RS485 bus via a FBA14 by means of a 2-wire screened bus line (e.g. telephone line). The meter reading and the momentary capacity are transferred to the bus – e.g. for transfer to an external computer or a Professional Smart Home controller – and is also transferred to the wireless network via the FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the operating instructions. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. The power consumption is displayed with a LED flashing 1000 times per kWh next to the display. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230 V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display.