Register to unlock your exclusive B2B prices and start shopping. Sign up now!
Similar figure image 1

RCBO, 6 kA, 1P+N, type A, 30 mA, B-char, In: 16 A, Un AC: 230 V

In stock: Yes Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
24,25 € per pcs
This price is valid until 31.12.25 or while stock lasts
EAN: 4001869306728
MPN: 5SU1356-6KK16
Box: 1
Estimate delivery time at our warehouse (approx.): 1-4 weeks

Technical Information

Item condition New
Manufacture name RCBO, 6 kA, 1P+N, type A, 30 mA, B-char, In: 16 A, Un AC: 230 V
Brand Siemens
Categories Earth Leakage Breakers (RCBO)
Country of origin RO
Harmonized System Code 8536 2010 00
Rated current 16 A
Rated voltage 230 V
Rated fault current 0.03 A
Leakage current type A
Degree of protection (IP) IP20
Number of protected poles 1
Number of poles (total) 2

Packing details

Packing level 1 4001869306728

Other Technical data

Voltage type AC
Built-in depth 70 mm
Rated insulation voltage Ui 264 V
Surge current capacity 1 kA
Current limiting class 3
Over voltage category 2
Pollution degree 2
Width in number of modular spacings 2
Concurrently switching neutral conductor Yes
Rated short-circuit breaking capacity according to IEC 60947-2 15 kA
Connectable conductor cross section solid-core 0.75-35 mm²
Connectable conductor cross section multi-wired 0.75-35 mm²
With interlocking device Yes
Flush-mounted installation Yes
Anti-nuisance tripping version Yes
Rated impulse withstand voltage Uimp 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1 6 kA
Disconnection characteristic Undelayed
Rated short-circuit breaking capacity according to EN 61009 6 kA

Description

This component is designed to combine overcurrent protection and residual current protection in a single device. It interrupts the circuit during overload, short-circuits, or when earth leakage currents exceed safe thresholds. Used primarily in low-voltage systems for enhanced safety and compliance with electrical standards. ### Electrical Ratings Breaking capacity: 6 kA. Rated current (In): 16 A. Rated operational voltage AC (Un): 230 V. Sensitivity: Residual current threshold at 30 mA. ### Design Standard & Characteristics Type: Type A — detects alternating currents and pulsating DC up to specified limits. Poles configuration: Single pole + neutral (1P+N). Trip curve classification: B-characteristic — quick reaction to short-circuit conditions within lower range currents typical of household or small commercial use. - Designed for installation in distribution boards on DIN rail mounts. - Requires neutral wiring connection — not compatible with fully phase-only systems. - Not suitable for applications exceeding Un AC of 230 V. - Functional temperature range typically -10°C to +50°C. - For indoor use — may require additional enclosure against moisture/humidity risks.