Registrati per sbloccare i tuoi prezzi B2B esclusivi e iniziare ad acquistare. Registrati ora!
MD01 image 1
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor image 2
MD01 image 3
MD01 image 4
MD01 image 5
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor image 6
MD01 thumbnail 1
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
MD01 thumbnail 5
UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor thumbnail 6

UA16-30-10RA-85 Kondensatorschütz 380-400V 50Hz / 400-415V 60Hz

Solo su ordinazione
EAN: 3471522300850
MPN: 1SBL181024R8510
Scatola: 1
Prezzo (IVA esclusa)
48,55 €
per pz.
Quantità minima d'ordine: 1
Tempo di consegna stimato al nostro magazzino: 4-6 weeks
Prezzo valido fino al 01.01.99 o fino a esaurimento scorte

Informazioni tecniche

Condizione dell'articolo Nuovo
Nome del produttore UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz Contactor
Marchio ABB
Categorie Contattori per condensatori
Codice del Sistema Armonizzato 8536 4900 00
ETIM EC001079
Tensione nominale di alimentazione del comando a 50 Hz AC 380-400 V
Tensione nominale di alimentazione del comando a 60 Hz AC 400-415 V
Tipo di tensione di azionamento AC

Dettagli dell'imballaggio

Livello di imballaggio 1 3471522300850
Livello di imballaggio 2 3471522300850

Altri dati tecnici

Numero di contatti NO come contatti principali 3
Numero di contatti NC come contatti principali 0
Numero di contatti ausiliari NO 1
Numero di contatti ausiliari NC 0
Tipo di collegamento elettrico del circuito principale Connessione a vite
Potenza nominale veneziana a 400 V, 50 Hz 12.5 kvar

Download

Descrizione

The UA16-30-10RA 380-400V 50Hz / 400-415V 60Hz is a 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design. - Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.