Registrati per sbloccare i tuoi prezzi B2B esclusivi e iniziare ad acquistare. Registrati ora!
Room thermostat universal with display, LS range, white image 1
Room thermostat universal with display, LS range, white image 2
Room thermostat universal with display, LS range, white image 3
Room thermostat universal with display, LS range, white thumbnail 1
Room thermostat universal with display, LS range, white thumbnail 2
Room thermostat universal with display, LS range, white thumbnail 3

Termostato ambiente universale con Display, LS, colore bianco

Solo su ordinazione
EAN: 4011377126022
MPN: TRUDLS231WW
Confezione: 1
Prezzo (IVA esclusa)
313,77 €
per unità
Quantità minima d'ordine: 1
Tempo di consegna stimato al nostro magazzino: 4-6 weeks
Questo prezzo è valido fino al prossimo listino o fino a esaurimento scorte

Informazioni tecniche

Condizione dell'articolo Nuovo
Nome del produttore Room thermostat universal with display, LS range, white
Marchio Jung
Categorie Termostati ambiente
Paese di origine* DE
* Il Paese di origine effettivo può variare in base al lotto di fornitura. Per confermare il Paese di origine specifico, contatta il tuo referente.
Codice del Sistema Armonizzato 9032 1080 00
ETIM EC010927
Tipo di fissaggio Montaggio da incasso (intonaco)
Modello Dipendente dalla marca
Tipo di alimentazione 230 V AC
Campo di misura 5-30 °C
Grado di protezione (IP) IP31
Numero di moduli (sistema modulare) 0

Dettagli dell'imballaggio

Livello di imballaggio 1 4011377126022, 4011377126022
Livello di imballaggio 2 4011377126022

Altri dati tecnici

Larghezza 70 mm
Altezza 70 mm
Profondità 0 mm
Numero RAL 0
Con display Sì
Diametro 0 mm
Comando Pulsante
Tipo di sensore/sonda Bimetallo
Consumo energetico in standby (solstandby) 0 W
Tensione max. dei contatti 0 V
Con ricevitore No
Con circuito acqua potabile No
Numero di uscite riscaldamento 1
Numero di uscite raffreddamento 1
Con segnalazione acustica No
Indicazione della temperatura Sì
Adatto per riscaldamento Sì
Carico max. dei contatti 0 A
Differenziale di commutazione 0.5 K
Sensore esterno No
Differenziale di commutazione regolabile No

Descrizione

Automatic control with programmable time and temperature settings possible with white illuminated display screw fixing only, without claws Delivery capacity is ensured until the end of March 2021.   Intended use Measurement and feedback control of the room temperature Measuring and controlling the floor temperature Room temperature control via floor heating with a limiting function (for example in conjunction with tiled stoves) Can be used for "heating only" or "cooling only" Installation in flush box according to DIN 49073 Only for use in dry, enclosed rooms   Product characteristics Large display with backlighting Text display for self-explanatory operation Programmable even when the controls are removed Different user languages can be selected Real-time clock with automatic summer/winter time changeover Internal temperature sensor An external remote sensor can be connected Three selectable and adjustable time temperature programs for automatic mode A maximum of nine operating times per day (the setting can also be terminated after a specific operating time) Can be individually programmed every day, or a block of operating times can be set: workdays/non-workdays, all days the same Can be manually adjusted at any time "Vacation" mode with the entered date (from/to) "At-home" mode (present) Short-time timer ("party function") Frost protection function Display of energy consumption for electric heating systems Pulse width modulation (PWM) or two-point control system Adjustable cycle time (PWM), hysteresis and minimum on/off time (two-point) Switch-on delay, such as for burners (with two-point control) Adaptation to valves normally open or normally closed) Valve protection (as a room temperature controller with and without a limiting function) Separate resetting of user and installer settings Heating interruption acc. to EN 50559 adjustable (not for valves opened without power)   The control method depends on the type of heating and is determined by the installer: Room temperature controller: The heating is turned on when the room temperature falls below the set target temperature (measured with an internal sensor or external remote sensor). Floor temperature controller: The underfloor heating is turned on when the floor temperature falls below the set target temperature (measured using an external remote sensor). Room temperature controller with a limiter (in conjunction with underfloor heating): The room temperature is measured and regulated using the internal sensor. An additional external remote sensor is connected to measure the floor temperature, and a target temperature range for the floor is set. The room temperature control is deactivated when the floor temperature is outside of this range. If temperature falls below this range, the heater is turned on, and if the temperature is above this range, the heater is turned off independent of the current room temperature.