Informazioni tecniche
| Condizione dell'articolo |
Nuovo |
| Nome del produttore |
Wireless single-phase energy meter |
| Marchio |
ELTAKO
|
| Categorie |
Dispositivi bus KNX/Modbus
|
| Paese di origine* |
CN |
|
* Il Paese di origine effettivo può variare in base al lotto di fornitura.
Per confermare il Paese di origine specifico, contatta il tuo referente.
|
| Codice del Sistema Armonizzato |
8526 9200 00
|
| ETIM |
EC001102
|
| Modello |
Altro |
| Tipo di collegamento |
Dritto |
| Interfaccia impulsi S0 |
No |
| Classe di precisione |
1 |
Dettagli dell'imballaggio
| Livello di imballaggio 1 |
4010312311059, 4010312311059 |
| Livello di imballaggio 2 |
4010312311059 |
| Livello di imballaggio 3 |
4010312311059 |
Altri dati tecnici
| Sistema bus KNX |
No |
| Sistema bus radio |
Sì |
| Sistema bus Powernet |
No |
| Commutatore tariffario |
No |
| Potenza reattiva |
No |
| Omologato PTB |
No |
| Altri sistemi bus |
No |
| Sistema bus LON |
No |
| Sistema bus radio KNX |
No |
| Radio bidirezionale |
No |
Download
Descrizione
Wireless single-phase energy meter, maximum current 65A. Only 0.5 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. This single-phase energy meter measures active energy by means of the current between input and output and transmits the current power and meter reading over the Eltako wireless network. Accuracy class B (1%). Evaluation and smart link via Smart Home-Controller. The internal power consumption of max. 0.5 watt active power is not metered. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1 phase conductor with a max. current up to 65A can be connected. If the anticipated load exceeds 50%, maintain an air gap of ½ pitch unit to the devices mounted adjacently. If necessary, use spacer DS12. The inrush current is 40mA. The consumption is saved to a non-volatile memory and is immediately available again after a power failure. Wireless telegrams: A telegram is transmitted within 60 seconds if the power status changes by min. 10 percent. A change in meter reading is transmitted immediately. A full telegram comprising meter reading and power status is transmitted every 10 minutes. When the power supply is switched on, a teach-in telegram is sent to teach in the associated energy consumption indicator. If the L input and the L output were interchanged when hooked up, a normal rate (HT)/off-peak (NT) switchover telegram is transmitted to indicate the hook-up error.