Registrati per sbloccare i tuoi prezzi B2B esclusivi e iniziare ad acquistare. Registrati ora!
Self-learning mains disconnection relay, 1 NO contact 10A image 1

Self-learning mains disconnection relay, 1 NO contact 10A

Solo su ordinazione
EAN: 4010312203477
MPN: 61100530
Confezione: 1
Prezzo (IVA esclusa)
49,99 €
per unità
Quantità minima d'ordine: 1
Tempo di consegna stimato al nostro magazzino: 2-4 weeks
Prezzo valido fino al 31.12.26 o fino a esaurimento scorte

Informazioni tecniche

Condizione dell'articolo Nuovo
Nome del produttore Self-learning mains disconnection relay, 1 NO contact 10A
Marchio ELTAKO
Categorie Interruttori generali
Paese di origine* CN
* Il Paese di origine effettivo può variare in base al lotto di fornitura. Per confermare il Paese di origine specifico, contatta il tuo referente.
Codice del Sistema Armonizzato 8536 5080 00
ETIM EC001651
Corrente nominale 10 A
Tensione nominale 250 V
Frequenza nominale 50 Hz
Corrente di picco all'accensione 20 mA
Monitoraggio della tensione DC

Dettagli dell'imballaggio

Livello di imballaggio 1 4010312203477, 4010312203477
Livello di imballaggio 2 4010312203477
Livello di imballaggio 3 4010312203477

Altri dati tecnici

Tipo di fissaggio Altro
Profondità di incasso 26 mm
Larghezza in moduli 0
Corrente max. di commutazione (cos phi = 0,6) 10 A
Carico max. lampade a incandescenza 1000 W
Carico max. lampade fluorescenti 1000 VA
Carico max. lampade fluorescenti (circuito doppio) 1000 VA
Carico max. lampade fluorescenti (compensazione in parallelo) 500 VA
Grado di protezione (IP) IP20

Download

Descrizione

1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 1000W. Standby loss 0.8 watt only. Built-in device for installation. 45mm long, 45mm wide, 26mm deep. 230V supply voltage and switching voltage. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The FR61-230V mains disconnection relay disconnects the power supply once all series connected loads are turned off, thus preventing any electromagnetic interference fields from occurring. Small loads up to 20mA are acceptable and, once major loads are disconnected, they do not prevent field disconnection. There is no need to manually set the limit. It is learned by the FR61. Loads drawing more than 200mA are consistently defined as loads which should cause the line power to be connected. As long as no major load is turned on, one pole of the monitored circuit remains isolated from the mains. Neutral and earth are connected continuously to avoid acting as an aerial. A DC voltage of 230V DC with an extremely low residual ripple is applied for monitoring. Therefore, it is prohibited to bridge the relay contact, which would ultimately cause device failure. When a load is turned on, the mains disconnection relay connects the phase. If the phase is switched on for the first time and after a power failure the FR61 automatically learns in again: At first an inrush current of 30mA is specified. If a new small load is switched on for more than 24 hours, the total current drawn by the monitored circuit is less than 200mA, and in the meantime the light has been switched on and off, the new load is learned in and the conductor is switched off. This learn-in mode can be realised immediately after connection of the new load by briefly switching off the MCB.