NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right image 1
NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right image 2
NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right image 3
NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right image 4
NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right thumbnail 1
NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right thumbnail 2
NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right thumbnail 3
NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right thumbnail 4

Earth-fault release, 30mA, 4p, right

Solo su ordinazione
EAN: 4015081044160
MPN: 104606
Confezione: 1
Prezzo (IVA esclusa)
303,95 €
per unità
Quantità minima d'ordine: 1
Tempo di consegna stimato al nostro magazzino: 4-6 weeks
Prezzo valido fino al 24.12.26 o fino a esaurimento scorte

Informazioni tecniche

Condizione dell'articolo Nuovo
Nome del produttore NZM1-4-XFI30R Earth-fault release, 30mA, 4p, right
Marchio EATON
Categorie Sganciatori e unità di protezione
Paese di origine* CZ
* Il Paese di origine effettivo può variare in base al lotto di fornitura. Per confermare il Paese di origine specifico, contatta il tuo referente.
Codice del Sistema Armonizzato 8538 9099 00
ETIM EC001021
Corrente nominale di cortocircuito 0.03 A
Tensione nominale di alimentazione del comando a 50 Hz AC 200-415 V
Tensione nominale di alimentazione del comando a 60 Hz AC 200-415 V
Tensione nominale di alimentazione del comando DC 0 V
Tensione nominale d'impiego max. Ue 415 V

Dettagli dell'imballaggio

Livello di imballaggio 1 4015081044160

Altri dati tecnici

Ritardo regolabile No
Ritardo max. all'accensione 30 ms

Download

Descrizione

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: approved according to IEC/EN 60947-2 not UL/CSA approved. Suitable for use in three- and single-phase systems. Pulse current sensitive according to core-balance principle. For 3 and 4 pole NZM1(-4) circuit-breakers and switch-disconnectors N1(-4).mains voltage independent Ue = 200 .. 415 V 50/60 Hz. At I △n = 0.03 A: delay time t v always fixed setting to 10 ms. Warning message > 30 % I △n by yellow LED . Trip indication max. 2 auxiliary contacts (HIAFI) can be fitted by user: N/O = M22-K01, N/C = M22-K10 are reset via the reset button. If the trip-indicating auxiliary contact in the fault current block is used, the N/C contacts operates as a N/O contact and the N/C contact operates as an N/O contact. Double contact not permissible. Not in combination with insulated enclosure or main switch assembly kit for side panel mounting with mounting bracket. NZM1-XFI...R can not be used in combination with lower cover NZM1-XUSA.NZM1-XFI…U not in combination with shunt or undervoltage release, early-make auxiliary contacts . Rated ultimate short-circuit breaking capacity is determined by fitted NZM1, NS1. When using a switch-disconnector N1, by the back-up fuse to be used. See technical data. Can be used for NZM1-4, N1-4