Registrati per sbloccare i tuoi prezzi B2B esclusivi e iniziare ad acquistare. Registrati ora!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
KA4269 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC image 5
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
KA4269 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC thumbnail 5

KA4269 Mess- und Wandlerfeld BH5 vorverdrahtet mit Zählerkreuz

Solo su ordinazione
EAN: 4011617350279
MPN: 2CPX035027R9999
Scatola: 1
Prezzo (IVA esclusa)
3 033,15 €
per unità
Quantità minima d'ordine: 1
Tempo di consegna stimato al nostro magazzino: 4-6 weeks
Prezzo valido fino al 01.01.99 o fino a esaurimento scorte

Informazioni tecniche

Condizione dell'articolo Nuovo
Nome del produttore KA4269 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC
Marchio ABB
Categorie Quadri per contatori
Codice del Sistema Armonizzato 8537 1098 00
ETIM EC000263
Con cablaggio Sì
Numero di armadi contatore 1
Vano collegamenti inferiore Con sbarra collettrice a 5 poli
Grado di protezione (IP) IP2XC
Corrente nominale dell'interruttore generale 250 A

Dettagli dell'imballaggio

Livello di imballaggio 1 4011617350279

Altri dati tecnici

Colore Grigio
Larghezza 500 mm
Modello A 2 livelli
Altezza 1350 mm
Numero RAL 7035
Con piastra di montaggio No
Vano collegamenti 300 mm
Larghezza in moduli 24
Numero di campi TSG 1
Numero di file di distribuzione 0
Modello del coperchio Chiuso con prefissaggio

Download

Descrizione

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, EN 61439-3, Rated operational voltage 415V AC 50/60 Hz, rated current 220 A, Rated current of the assembly of switchgear and controlgear InA 174 A, in RAL 7035, dimensions in mm (H x W x D): 1350 x 500 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Pre-wired according requirements DSO, voltage path 3 low voltage path switches B10/25kA overvoltage path category 3, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse switch disconnector NH1/250A, current transformer range CT mounting pad with CT rail 30 x 5 mm, parting point after the current transformer Switch 250 A / 3-pole and 2 fuse switch disconnectors NH00/160 A (M8), primary wiring Cu-Busbar 30 x 5 mm, Accessible: Cu busbar connection to baying board or additional incomer cabinet on the side. Outgoing: terminals screws to fuse disconnetor and PE+N busbar, Connection N+PE (M8), Note: In case short circuit is > 25 kA, Backup protection required for voltage path circuit. Short circuit value to be obtained from DSO. Incomer housing EK230 may be required, busbar terminals should be ordered seperately, Grid unit 9 GU, Overall height 5, panel width 2, Space units 216, covers out of Plastic, Quick sealable connection, RAL 7035