trilux in ground luminaires project context and scope

Urban plazas, façades, and approach roads need sealed optics, predictable glare control, and housings that tolerate water, de-icing salts, and wheel loads. On 220–240 V AC systems with SELV secondaries, expect PF ≥ 0.95 at driver level and THD ≤ 10–15 %. Lumen packages run ~300–4000 lm with CCT 2700–4000 K, CRI 80/90, and SDCM ≤ 3; beam sets include symmetric narrow to wide, wall-wash, and grazing. Installers standardise connectors, loop-through options, and drain planning so trilux in ground luminaires stay dry, serviceable, and consistent across phases.

trilux buried led lights product range and optical options

Families span compact uplights for bollard-scale accents, 120–180 mm bodies for tree and column washes, and heavy-duty drive-over units up to 2,000–5,000 kg static load. Optics use TIR lenses or micro-reflectors; glare kits include half-shields, cowls, and honeycomb. Deck rings come in 316 stainless or anodised aluminium with anti-slip textures. Where pathways double as fire lanes, tilt-adjust carriers let trilux buried led lights align precisely without breaking IP.

trilux recessed ground lighting technical specifications and standards

Typical ratings: IP67/68 with IK08–10 lenses (tempered glass 8–12 mm), −30…+50 °C operation, salt-mist–resistant hardware, and 2–6 kV surge L–N. Cable glands are nickel-plated brass or stainless; terminals accept 0.5…2.5 mm² Cu, strip 8–12 mm, torque 0.6–1.2 Nm. Housing materials: cast aluminium with hard anodise or polymer composites to resist galvanic attack. Conformity anchors: EN 60598-1/-2-13, IEC/EN 61347 and IEC 62384 (drivers), EN 60529 (IP), EN 62262 (IK), and LM-80/TM-21 for lifetime evidence. With correct bedding and drainage, trilux recessed ground lighting sustains photometry and seal integrity over full maintenance cycles.

trilux outdoor inground fixtures applications and load classes

Plazas, hotel drop-offs, and retail forecourts need drive-over certification; parks and pathways typically sit in walk-over classes with shallower cans. Near façades, asymmetric grazers emphasise verticals without hotspot streaks; on trees, medium beams prevent trunk burn while preserving crown sparkle. For coastal promenades, specify marine-grade rings and sealed fasteners. In flood-prone zones, trilux outdoor inground fixtures are set in gravel beds with drain risers below can level to keep hydrostatic pressure off the gasket stack.

trilux landscape ground lights integration with other brand systems

DALI-2 drivers align scenes with façade lines and landscape cues; time channels dim late-night while maintaining security lux. Where bus cabling is impractical, wireless bridges map zones back to BMS. Emergency is rarely required outside, but monitored status still helps maintenance—temperature and runtime counters feed dashboards through gateways. Using trilux landscape ground lights with matched drivers and connectors keeps inrush tables, address maps, and label fonts the same across the estate.

trilux architectural inground luminaires selection notes for B2B buyers

Start with the task: accent, wall-graze, or wayfinding. Fix beam, lumen class, and CCT/CRI; verify UGR proxies where sightlines cross. Confirm load rating (walk vs drive-over), trim material, and anti-slip finish. Detail the civil work: sleeve depth, cable entry, gland direction, and drain path; avoid sealed pots without relief. Publish tc points, maximum LED lead lengths, and shield strategy. When trilux architectural inground luminaires share sleeve geometry across sizes, stock holding and replacement time drop sharply.

trilux waterproof recessed lights advantages of working with Bankoflamps

Civil and electrical timelines rarely align; we package sleeves, cans, rings, drivers, and seals by zone so trenches close once. You get project-specific pricing, near-hour quotes by EAN/MPN, and live EU stock before crews book night shifts. The portal shows lead times, shipment tracking, and downloadable price lists with validity dates you can plan against. Trusted clients can use post-payment up to 30 days. We consolidate room- and zone-bundled consignments and your account manager cross-checks optics, load classes, IP/IK, inrush/MCB data, drainage notes, and labeling against drawings—keeping trilux waterproof recessed lights installs site-ready across France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.

Product range and series overview

  • Walk-over uplights: shallow bodies for paths and decks; opal or clear glass with low-glare rings.
  • Drive-over units: deep cans, heavy lenses, and reinforced frames; tilt modules for post-install alignment.
  • Grazers and washers: asymmetric optics for façades and columns; precise cutoff to avoid window glare.
  • Accessory sets: anti-glare baffles, cowls, honeycomb, marine-grade trims, and vandal-resistant screws.

Technical specifications and standards

Supply via SELV constant-current 200–1050 mA or CV 24/48 V where modules require; PF/THD per driver. Glass 8–12 mm tempered, chem-etched for slip resistance; gaskets in silicone or EPDM. Drainage layer of washed gravel or geotextile bed recommended; cable loops below can base to stop wicking. EMC per EN 55015/61547; harmonics per EN 61000-3-2/-3-3; corrosion guidance per ISO 9227 where coastal.

Applications and compatibility

  • Entrances and drop-offs: drive-over beams to highlight portals; DALI-2 scenes for event modes.
  • Retail streetscapes: tight accents on signage, medium floods for brand façades.
  • Parks and campuses: warm CCT path markers with low glare; cut-off accessories in wildlife corridors.

Heritage façades: high CRI and stable dim-to-low for media shoots, controlled from central scheduling.
Systems interconnect cleanly with Trilux drivers, façade projectors, and control gateways so one addressing and spare-kit logic spans the whole exterior package.