Technical Information
| Item condition |
New |
| Manufacture name |
LB Management motion detector 1.1 m CD17180WUPT |
| Brand |
Jung
|
| Categories |
Switches
Motion & Presence Sensors
|
| Country of origin* |
DE |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Harmonized System Code |
9031 8080 00
|
| ETIM |
EC000138
|
| Mounting method |
Flush mounted (plaster) |
| Max. transmission range frontally |
30 m |
| Max. transmission range sideways |
15 m |
| Mounting height |
1.1 m |
| Detection angle horizontal |
180 ° |
Packing details
| Packing level 1 |
4011377167964, 4011377167964 |
| Packing level 2 |
4011377167964, 4011377167964 |
Other Technical data
| Colour |
Platinum |
| Model |
Movement sensor |
| Halogen free |
Yes |
| Creep-under protection |
No |
| Staircase monitoring |
No |
| Suitable for wireless transmission |
No |
| Material quality |
Thermoplastic |
| Material |
Plastic |
| Response value sensitivity adjustable |
Yes |
| Dim function with dimmer basic element |
No |
| Diameter detection range on floor |
0 m |
| HVAC-control |
No |
| Constant light control |
No |
| RAL-number (similar) |
0 |
| Teach-function for response value luminosity |
No |
| Networkable |
Yes |
| Operation mode switch |
No |
| Animal zone |
No |
| Min. switch-on time |
120 s |
| Max. duty cycle |
2 min |
| Suitable for degree of protection (IP) |
IP44 |
| Response value luminosity adjustable |
Yes |
| Switch-off delay self-learning |
No |
Downloads
Description
LB Management motion detector 1.1 m CD17180WUPT.Utilized in flush-mounted switch systems for detecting motion.Operates within standard IP44 protection limits for indoor/outdoor applications. Mounting type:Flush mounted (plaster), Material:Plastic (Thermoplastic).Finish color:Platinum.Equipped with horizontal detection angle of 180° at mounting height of 1.1 m, designed for medium-range frontal transmission up to 30 m and sideways capability reaching 15 m.Maximum duty cycle setup capped at 2 minutes;minimum activation window defined at 120 seconds.Response value sensitivity/luminosity is adjustable on-site, while networkable functionality enabled;unit not wireless-compatible yet rigidly integrated through hardline installs. No supplementary detection zones;operates without creep-under coverage or HVAC interfacing features—tailored specifically for primary switching response mechanisms without staircase monitoring provisions or auxiliary dimmer control layers embedded into operational design logic stack.