S&P hardware covers airflow, water movement, and gate control under one ecosystem. The catalog is organised so specifiers can mix roof and inline fans, booster and drainage pumps, and motorised operators on the same project without reinventing wiring, controls, or service parts.
s and p ventilators pumps and gate operators portfolio and use cases
Installers see three working families on most jobs:
- Ventilators: roof, wall, and inline axial/centrifugal units for offices, retail back-of-house, kitchens, and plant rooms. Airflow classes from 100–30,000 m³/h with static pressure capability up to 800 Pa on backward-curved wheels. EC and AC motor options at 230 V single-phase and 400 V three-phase; typical motor protection IP54–IP55, insulation class F, ambient −20…+60 °C.
- Pumps: cold-water boosters for washrooms and catering points, condensate and drainage pumps for AHUs and basements. Heads to 40–60 m depending on model, flow to 12–15 m³/h in compact sets; stainless wetted parts where hygiene or light chemicals are present.
- Gate and door operators: sliding and swing actuators for service yards, loading docks, and controlled staff parking. Duty cycles sized for daytime peaks; integrated limit sensing and soft-start keep mechanical shock off tracks and hinges.
This mix lets planners handle extraction, pressure control, and access on a single BOM with common accessories.
s-p ventilation and pump systems ranges and performance
Ventilation ranges
- Roof axial for straightforward extract and smoke relief in low-pressure applications; matched cowls, backdraft dampers, curb adapters.
- Inline mixed-flow where long duct runs or acoustic constraints exist; EC variants with stepless control and ηtot gains on part-load.
- Centrifugal cabinet units for high-loss ductwork and filtration; side discharge options ease plant-room layouts
Pump anges
- Multistage boosters with variable-speed drives to stabilise pressure under fluctuating load; typical setpoint 2.5–4.5 bar.
- Sump and drainage pumps with vortex or channel impellers to pass debris in basements and light industrial pits.
- Condensate pumps for fan-coils and split AC; low-profile trays for ceiling voids, lift 5–10 m with non-return valves.
Noise control uses EC commutation, acoustic jackets, and resilient mounts; EC lines cut electrical noise on lighting circuits and reduce transformer heating in legacy boards.
s-p gate automation applications and compatibility
Operators cover sliding gates up to 600–1200 kg and swing leaves to 3–5 m, with programmable speed and soft stop to protect hardware. Control inputs accept dry contact and 24 V logic; radio receivers and loop detectors integrate with access control. Safety edges and photocells land on dedicated terminals; manual release is tool-operable during outages. Finish and IP ratings suit semi-outdoor yards and canopies; matched racks, arms, and track hardware keep installs fast.
Controls and integration you can reuse across packages
Where a site already runs lighting and HVAC on groups, the same controller family can time-slice ventilation boost, pump duty/standby changeover, and gate locking windows. For refits, s-p motorized control units provide relay I/O, 0–10 V, and bus gateways so electricians keep the wiring story simple.
Product range and series overview
Build from repeatable bundles:
- Core ventilation kit: inline mixed-flow or centrifugal fan sized to duct losses, flexible connectors, backdraft damper, anti-vibration feet, and a wall controller.
- Booster set: twin vertical multistage pump on baseframe with inverter, expansion vessel, and isolation valves for quick swap-out.
- Yard access pack: sliding operator with toothed rack, safety photocells, control board enclosure, beacon, and manual release kit.
Accessory logic repeats—spigots, silencers, weather cowls, float switches, and check valves—so spares stay lean across buildings.
Applications and compatibility with other building systems
Retail and office shells use silent inline fans for toilets and cores, cabinet fans for kitchen extracts, and condensate pumps in ceiling voids. Warehouses combine roof fans with make-up air to stabilise pressure when dock doors open. Hotels pair booster sets for guest floors with drainage pumps at plant. Service yards specify operators with heavy-duty racks and frost-tolerant enclosures. Vent and pump alarms ride the same BMS backbone as luminaires and emergency testing, so maintenance sees one dashboard.
Procurement note: where drawings use generic terms, the phrase s-p fans and pumps is often accepted to group ventilation extract, make-up air, boosters, and drainage on a single RFQ line.
Selection criteria for B2B clients
- Airflow and pressure Size fans to duty points, not free air. Confirm duct losses, filters, backdraft dampers, and grille pressure.
- Efficiency and control Prefer EC for variable occupancy; use 0–10 V or bus control to trim part-load kWh.
- Acoustics Check breakout and regenerated noise; add silencers and elastomer mounts near offices or guest rooms.
- Hydraulic duty For boosters, map peak and diversity; hold N+1 where service continuity is critical. For drainage, confirm solids handling and duty/standby logic.
- Environment Pick IP and materials for grease, salt, or chlorine; keep cable glands and drains above flood lines.
- Access control Match operator thrust/torque to leaf mass, add safety edges and photocells, and verify emergency release policy.
Intgration and controls
Where sites standardise on a head-end, s-p automation devices expose speeds, alarms, and energy via BACnet or Modbus; small installs use wall plates and simple relays. Fire and smoke interfaces provide run/stop and damper status signals; pump skids report run hours and fault codes for planned maintenance.
Advantages of working with Bankoflamps
You receive project-specific B2B pricing aligned to the real schedule, a named account manager, and live EU stock visibility before commitment. Most quotes land in about one hour. Ordering by EAN/MPN keeps ERP data clean; downloadable price lists stay current for tenders. Your portal shows lead times and order status, plus purchase-history analytics to consolidate SKUs. For trusted clients we support post-payment up to 30 days and plan consolidated shipments with clear price-validity windows across phases.