Technical Information

Item condition New
Manufacture name OVR T1-T2 4L 12.5-275s P TS QS Surge Protective Device
Brand ABB
Categories Surge Protection Devices (SPD)
Harmonized System Code 8536 3090 00
Lightning impulse current (10/350 µs) 12.5 kA
Voltage protection level 0.8 kV
Max. continuous voltage AC 275 V
Nominal voltage AC 230 V
Nominal voltage DC 350 V
Test class Type 1 + 2
Voltage protection level L-N 1.3 kV
Max. continuous voltage DC 350 V
Degree of protection (IP) IP20
Max. PV-voltage 0 V
Voltage protection level N-PE 1.3 kV
Voltage protection level L-PE 2.8 kV

Packing details

Packing level 1 3660308524942
Packing level 2 3660308524942
Packing level 3 3660308524942

Other Technical data

Mounting method DIN rail (top hat rail) 35 mm
Number of poles 4
Construction size 4 modular spacing
Remote signalling Yes
Follow current extinguishing capability 0 kA
Signalling at the device Optic
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
Voltage protection level (DC+ - DC-) 0 kV
Voltage protection level (DC+/DC- - PE) 0 kV
Specific energy (W/R) 0 kJ/Ohm
Energy-coordinated protection effect with regard to the terminal equipment No
System configuration DC No
System configuration IT No
System configuration TN No
System configuration TN-C No
System configuration TN-S Yes
System configuration TT No
System configuration other No
System configuration TN-C-S No
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Voltage switching spark gap technology FALSE
Overcurrent protected voltage tapping FALSE