OVR PV T2 40-1500 P TS Surge Protective Device

In stock: No Vendor stock: No Minimal order quantity: 1
Price (excl. VAT):
335,45 € per pcs
This price is valid until 31.12.30
EAN: 4053546050288
MPN: 2CTB802401R1500
Box: 1
Estimate delivery time at our warehouse (approx.): By request

Technical Information

Item condition New
Manufacture name OVR PV T2 40-1500 P TS Surge Protective Device
Brand ABB
Categories Surge Protection Devices (SPD)
Harmonized System Code 8536 9095 00
Voltage protection level 4 kV
Nominal discharge surge current (8/20) 15 kA
Nominal voltage DC 15000 V
Degree of protection (IP) IP20
Max. PV-voltage 15000 V
System configuration DC Yes
System configuration IT No
System configuration TN No
System configuration TN-C-S No

Packing details

Packing level 1 4053546050288

Other Technical data

Mounting method DIN rail (top hat rail) 35 mm
With remote signalling contact No
Number of conductors (without earthing) 2
Construction size 3 modular spacing
Max. continuous voltage AC 1500 V
Category type 2 Yes
Signalling at the device None
Max. continuous voltage DC 15000 V
Integrated backup fuse No
Max. conductor cross section solid (solid, stranded) 35 mm²
Max. conductor cross section flexible (fine-strand) 25 mm²
System configuration TN-C No
System configuration TN-S No
System configuration TT No
System configuration other No
Max. discharge surge current (8/20) 40 kA
Short-circuit breaking capacity (Isccr) 10 kA
Integrated short-circuit protection No
Leakage-current free No

Downloads

Description

Überspannungs-Schutzeinrichtung OVR PV T2 schützen elektrische Anlagen vor Überspannungen. Sie sind nach IEC 61643-31, DIN EN 50539-11 und UL 1449 5th Ed Typ 2 geprüft. Der Status der Überspannungs-Schutzeinrichtung erfolgt über eine Funktionsanzeige. OVR mit Telesignal "TS" sind optional mit einem potentialfreien Wechselkontakt ausgestattet und können den Staus zum Beispiel an ein Monitoring-System weitermelden. Die Anwendung ist speziell auf der DC-Seite von Photovoltaik-Anlagen.