Current relay, 1 CO contact 16A
Ir noliktavā: Nē
Piegādātāja krājumi: Nē
Minimālais pasūtījuma daudzums: 1
Šī cena ir spēkā līdz 24.12.25
Paredzamais piegādes laiks mūsu noliktavā (aptuveni):
4-6 weeks
Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
Current relay, 1 CO contact 16A |
Zīmols |
ELTAKO
|
Kategorijas |
Monitoring Relays
|
Izcelsmes valsts |
CN |
Harmonizētās sistēmas kods |
8536 4900 00
|
Strāvas mērīšanas diapazons |
0.1-32 A |
Iespējama vienfāzes zemstrāva |
No |
Funkcija Līdzstrāvas histerēze |
No |
Elektriskā pieslēguma veids |
Skrūvju savienojums |
Kontaktu skaits kā parasti atvērtam kontaktam |
0 |
Iepakojuma informācija
Iepakojuma līmenis 1 |
4010312205426, 4010312205426 |
Iepakojuma līmenis 2 |
4010312205426 |
Iepakojuma līmenis 3 |
4010312205426 |
Citi tehniskie dati
Platums |
18 mm |
Augstums |
58 mm |
Dziļums |
58 mm |
Ārējais strāvas transformators |
No |
Ar noņemamām skavām |
No |
Iespējama vienfāzes histerēze |
No |
Iespējama trīsfāzu histerēze |
No |
Iespējams trīsfāzu zem strāvas |
No |
Iespējama vienfāzes pārstrāva |
No |
Iespējama trīsfāzu pārstrāva |
No |
Satur funkciju DC-spriegums zem strāvas |
No |
Satur funkciju DC-sprieguma pārstrāva |
No |
Nominālais vadības barošanas spriegums pie AC 50 Hz |
250 V |
Maks. atļautais izslēgšanas aizkaves laiks |
120 s |
Min. regulējams izslēgšanas aizkaves laiks |
0 s |
Sprieguma veids iedarbināšanai |
AC |
Kontaktu skaits kā parasti slēgtam kontaktam |
0 |
Kontaktpersonu skaits kā maiņas kontaktpersona |
1 |
Lejupielādes
Apraksts
1 CO contact potential free 16A/250V AC. 230V LED lamps up to 200W, incandescent lamp load 2300W. Standby loss 0.8 watt only. Modular device for DIN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. With the patented Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 1(L) for this. This gives an additional standby consumption of only 0.1 watt. If the contact is used for controlling switching devices which do not perform zero passage switching themselves, (N) should not be connected because the additional closing delay otherwise causes the opposite effect. With an internal toroidal-core current transformer the single phase AC current flowing through a consumer V1 of 0.1 A up to max. 32 A is compared to the setpoint. When the latter is exceeded a relay switches off a consumer V2 connected to 2 within 0.5 seconds or switches on a consumer V3 connected to 3. Adjustment accuracy ±5%. From 25A the relay always switches on. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. The basis of current A will be set with the lower rotary switch A. The following basic values can be selected: 0.1A, 0.3A, 0.6A, 0.9A, 1.5A, 1.9A, 3.0A and 3.2A. The multiplier xA will be set with the middle rotary switch xA and offers values between 1 and 10. So currents starting from 0.1A (basis of current 0.1A and multiplier 1) can be set. OFF delay RV can be set with the upper rotary switch RV between 0 and 120 secs. The hysteresis is defined as approx. 25%. Status indication by LED. The measuring input M1-M2 is electrically isolated from power supply L-N and make contact 1(L)-2/3. Reference values larger than 32A can be adapted by an external measuring transformer.