Technical Information
| Preces stāvoklis |
Jauns |
| Ražotāja nosaukums |
6131/50-183-500 KNX Presence Cor. S |
| Zīmols |
ABB
|
| Kategorijas |
Bus System Devices (KNX/Modbus)
|
| Harmonizētās sistēmas kods |
8536 5080 00
|
| Modelis |
Klātbūtnes detektors |
| Autobusu sistēma KNX |
Yes |
| Autobusu sistēmas radio bieži |
No |
| Autobusu sistēma Powernet |
No |
| Ar autobusa savienojumu |
Yes |
| Citas autobusu sistēmas |
Nav |
| Autobusu sistēma LON |
No |
| Autobusu sistēma KNX radio |
No |
| Radio bieži divvirzienu |
No |
Iepakojuma informācija
| Iepakojuma līmenis 1 |
4011395216453 |
Citi tehniskie dati
| Montāžas metode |
Virsmas montāža (apmetums) |
| Krāsa |
Alumīnija |
| Virsmas aizsardzība |
Lakots |
| Aizsardzība pret šļūteni |
Yes |
| Kanālu skaits |
2 |
| Kāpņu telpas uzraudzība |
Yes |
| Materiāla kvalitāte |
Termoplasts |
| Maks. transmisijas diapazons frontāli |
10 m |
| Maks. pārraides diapazons uz sāniem |
15 m |
| Digitālo ieeju skaits |
0 |
| Materiāls |
Plastmasas |
| Apakšstacijas ieeja |
Yes |
| RAL numurs (līdzīgs) |
9006 |
| Mācīšanas funkcija reakcijas vērtības spilgtumam |
Yes |
| Darbības režīma slēdzis |
No |
| Caurspīdīgs |
No |
| Dzīvnieku zona |
No |
| Virsmas apdare |
Matt |
| Min. ieslēgšanās laiks |
10 s |
| Maks. cikls |
1092 min |
| Reakcijas vērtības spilgtums regulējams |
Yes |
| Izslēgšanas aizkaves pašmācība |
No |
| Optimāls montāžas augstums |
3 m |
| Min. iebūvētās instalācijas kastes dziļums |
0 mm |
| DALI-2 sertificēts |
No |
Lejupielādes
Apraksts
Detection range: rectangular. For mounting height of 3 m: frontal toward the detector at a max. of 20 m x 3 m (at a max. of 10 m x 3 m per side). Crosswise toward the detector at a max. of 30 m x 3 m (max. of 15 m x 3m per side). With integrated KNX bus coupler. Mounting height 27 mm. With 2 channels. Targeted for connection and disconnection of lights bands depending on the room brightness. Regulation in response to the movement possible. Using the device as presence and/or movement detectors. Detectors application with 2 power off stages. Detectors application with integrated monitoring function. Constant light switch with up to two independent channels. Constant light switch with max. 2 outputs for brightness-dependent switching of two light bands in the area. Ceiling mounting on suspended ceilings with spring clamps, on solid ceilings in surface-mounting boxes 6131/39-xxx(-500) or on VDE flush-mounted boxes with intermediate ring for VDE flush-mounted boxes 6131/38-xxx(-500). Suitable for false ceilings with a board thickness from 9 to 25 mm. Hole size: Ø 68 mm. Cannot be installed in British Standard or VDE flushmounted box. Recommendation: Installation housing from Kaiser HaloX-O (Art.no. 1290-40) with corresponding cover plates (1290-47 or 1290-85 for fair faced concrete) or IBTronic H120-68 from Spelsberg.