| Item condition | New |
| Manufacture name | Surge Protection Device Acti9 iPF K 65 3P+N 340V 65kA |
| Brand | Schneider Electric |
| Categories |
Surge Protection Devices (SPD)
|
| Country of origin* | CN |
| * The actual country of origin may differ depending on the delivery batch. To confirm the specific country of origin, please contact your account manager. | |
| Harmonized System Code | 8536 3030 00 |
| Voltage protection level | 1.5 kV |
| Nominal discharge surge current (8/20) | 20 kA |
| Nominal voltage AC | 260 V |
| Nominal voltage DC | 0 V |
| Voltage protection level L-N | 1.5 kV |
| Degree of protection (IP) | IP20 |
| Max. PV-voltage | 0 V |
| System configuration DC | No |
| System configuration IT | No |
| System configuration TN | No |
| System configuration TN-C-S | No |
| Packing level 1 | 3606480089800 |
| Packing level 2 | 3606480089807 |
| Packing level 3 | 3606480089808 |
| Mounting method | DIN rail (top hat rail) 35 mm |
| With remote signalling contact | No |
| Number of conductors (without earthing) | 3 |
| Construction size | 4 modular spacing |
| Max. continuous voltage AC | 260 V |
| Category type 2 | Yes |
| Signalling at the device | Optic |
| Max. continuous voltage DC | 0 V |
| Voltage protection level N-PE | 1.5 kV |
| Integrated backup fuse | No |
| Max. conductor cross section solid (solid, stranded) | 35 mm² |
| Max. conductor cross section flexible (fine-strand) | 35 mm² |
| System configuration TN-C | No |
| System configuration TN-S | Yes |
| System configuration TT | Yes |
| System configuration other | No |
| Max. discharge surge current (8/20) | 65 kA |
| Short-circuit breaking capacity (Isccr) | 0 kA |
| Max. overcurrent protection device, parallel connection (fuse) | 0 A |
| Max. overcurrent protection device, series connection (fuse) | 0 A |
| Integrated short-circuit protection | No |
| Integrated short-circuit protection selective to fuse gG | 0 A |
| Leakage-current free | No |
This Acti9 iPF K 65 product is a modular surge arrester. It protects 3P installations. The Imax maximum discharge current is 65kA .The In nominal discharge current is 20kA. The multi-pole single-piece surge arrester range is adapted for TT, TN-S, TN-C earthing systems. This type 2 incoming protection surge arrester is recommended for a very high risk level. The Uc maximum continuous operating voltage in common mode (between neutral and earth) is 260VAC. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 340VAC. The Up Voltage protection level is 1.5kV in common mode (between neutral and earth) and in differential mode (between phase and neutral). The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 72mm x (H) 81mm x (D) 69mm. The weight is 335g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with IEC 61643-11 and EN 61643-11 standards.