Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Wiha Tools, measuring instruments and protection

wiha measuring instruments overview and range

Built for panel shops, OEMs and field crews, this category brings together everyday meters and safety gear you actually use: true-RMS multimeters, slim AC/DC clamp meters, two-pole testers, installation testers (insulation/continuity), plus lockout/tagout and PPE add-ons. Wiha structures the range by job type (installation check, commissioning, diagnostics), safety category (CAT III/CAT IV), and kit format (bench rolls vs van sets). Most distributors keep meter kits with silicone leads, clips, spare fuses and soft cases ready to ship—fast movers that keep projects on schedule.

wiha hand tools and testing devices kits and fast movers

Think in three buckets.

  1. Handheld meters: compact service DMMs for 24 V rails and PLC I/O, mid-tier units with frequency/duty/temperature, and logging models for shift reports.
  2. Clamps: 400–1000 A AC/DC with inrush capture; slim jaws fit MCC corridors.
  3. Two-pole testers with LED/LCD and haptic feedback for safe “dead-test” before work.
    Procurement notes: buy meters as full kits (meter + silicone leads + croc clips + fuses + case). Stores like to stock one spare lead set per five meters—lost leads, not failed meters, cause most delays.

Product range and series overview

  • Installation testers: insulation up to 1000 V, fast continuity beeper, optional loop/earth where required.
  • Accessories: right-angle probe tips, magnetic straps, probe extenders, fuse packs, protective holsters.
  • Bench add-ons: torque drivers, ferrule crimpers and strippers that match terminal specs so wiring and verification happen in one pass.

Key features and ordering specs that matter

  • Safety first. CAT III/IV ratings with ceramic fuses; LoZ mode to kill ghost voltages on long runs.
  • Readability. Backlit 6k–10k count displays with bargraph; hold/min/max for transient checks on drives.
  • Ergonomics. Soft-grip housings, anti-roll boots, slim clamps for crowded feeders.
  • Durability. IP-rated shells, drop-tested corners, field-replaceable fuses and boots.
  • Kitting. Van pouches that fit a DMM, clamp, two-pole tester, and LOTO—one pick per technician reduces missed items.

Applications and compatibility

Commissioning MCCs, checking 24 V control rails, VFD troubleshooting, HVAC rooftops, pump galleries and packaging lines. Meters land next to push-in terminals, DIN rails and 24 V supplies; lead tips match common terminal test points. For basket building, add ferrules, marker sleeves, cable glands, PE/earth terminals, and wire duct so crews can fix and document in a single visit. Many teams label the metrology drawer “wiha measurement instruments” for calibration tracking.

Integration with other brand products

Square-profile ferrules seat cleanly in push-in clamps after you verify torque; jacket strippers expose braid lengths that fit shield clamps at gland plates; magnetic meter straps park safely on steel doors; clamp jaws slip between TS35 rails and duct covers. When you standardise on one lead system, testers, DMMs and clamps share tips—less hunting, faster FAT.

wiha electrical protection tools for safe commissioning

Lockout/tagout kits (breaker lockouts, hasps, tags), insulated mats/gloves, padlockable switch covers, and door-coupled isolator handles tighten procedures and keep audits clean. Surge-safe bench strips, holsters and blade guards protect tools and people. Common stocking rule: one LOTO kit per van, one per bench bay—cheap insurance that prevents expensive incidents.

wiha voltage testers selection and use cases

Two-pole testers with bright LEDs and vibration feedback are the go-to for verifying absence of voltage. Add phase rotation for motor swaps and single-pole phase detection for quick checks. Non-contact pens help trace energized trays without opening covers. Packaging is usually singles with caps and belt clips—simple to issue and track.

Selection criteria for B2B clients

  • Work zone & CAT rating. Match meter/tester CAT level to the highest fault energy you’ll encounter; err up, not down.
  • Function set. Everyday service needs V/A/Ω, True-RMS and continuity; add temperature and low-ohm for drives/heaters.
  • Form factor. Slim clamps for dense cabinets; large displays for dim plant rooms; two-pole testers for LOTO steps.
  • Throughput. Choose meters with fast beeper and auto-range that doesn’t hunt; right-angle tips speed dense I/O rows.
  • Fleet logic. Standardise leads/fuses across models; pick serialized tools for calibration records.
  • Kit completeness. Order meter + leads + clips + fuses + holster + LOTO in one line to avoid mid-build holds.

Advantages of working with Bankoflamps

You get individual B2B pricing and custom offers, a dedicated account manager, and real-time stock across EU warehouses. Quotes return fast (≈1 hour). Ordering by EAN/MPN is straightforward with downloadable, always-current price lists. We provide lead-time tracking, order-status updates and purchase-history analytics, plus post-payment up to 30 days for trusted clients. Consolidated shipments cut freight with stable pricing validity. We serve France, the Baltics, Germany, Spain, Italy, Belgium and the Netherlands.