Weidmüller Electric box (breaker panel)

weidmuller distribution boards range and buyer’s map

Compact low-voltage assemblies for machine cells, building risers, and OEM skids. Weidmüller structures the category by footprint (mini wall-mount to floor-standing), ingress class (IP30–IP66), and internal systems (DIN TS35 rails, copper busbars, PE/N kits). Buyers are panel shops, HVAC contractors, and integrators who need clean wiring space that drops into weidmuller power distribution systems without reworking cutouts or accessories.

weidmuller electrical panels form factors and series

Families split into shallow wall units for corridors and lineside stations, deeper bodies for drives and soft starters, and split-door formats for metering compartments. Depth options support standard device heights so breakers, surge modules, and terminals align. Most distributors stock neutral RAL 7035 steel first; stainless and polycarbonate land on short lead times. Fast movers: 12–36 module wall enclosures with reversible doors, plus midsize cabinets that carry two full DIN rows and a cable chamber.

Product range and series overview

  • Cylindrical lock or quarter-turn latch doors, clear or solid, with left/right field reversal.
  • Internal kits: caged-nut plates, slotted mounting plates, and multi-rail frames for dense I/O.
  • Thermal options: gland plates, louvered vents, and fan kits sized to standard cutouts.
  • Packaging: each housing ships with rail hardware, earth studs, and a marker strip set—installers can start wiring on day one.

Key features and options that matter at ordering

  • IP ratings from IP30 (dry plant rooms) to IP66 (washdown and outdoor covers).
  • Impact classes IK07–IK10; hinges rated for frequent access on service doors.
  • Knockouts and gland plates sized to M16–M40; depth spacers for large bend radii.
  • Copper kit choices: PE/N bars with insulated supports, cross-link jumpers, and split neutral options.
  • Ready rails: pre-cut TS35 rails and end-stops reduce build hours; optional backplates for heavy drives.
  • Documentation space: door pockets and marker carriers sized to A5/A4 service sheets.

weidmuller modular distribution enclosures configuration and accessories

These let you build a repeatable layout: stackable rail frames, adjustable cable ducts, and snap-in partitioning keep segregation clear between power, control, and comms. Add windowed doors where status needs to be visible and lift-off hinges for quick subpanel swaps. Installers like the shared hole patterns—brackets, filters, and light kits line up across sizes with no drilling.

Applications and compatibility

Used in conveyors, packaging cells, boiler rooms, pump skids, and building risers. Cabinets accept Weidmüller terminal blocks, surge protection, circuit breakers, and managed switches on the same TS35 rails. For field spurs, pair with weidmuller junction boxes to keep IP integrity outside the main enclosure. See also Weidmüller Terminal Blocks, Power Supplies, Marking Systems, and Cable Glands to complete the basket on one PO.

Integration with other brand products

RockStar connectors simplify machine split points; pre-wired plinths accept common base plates. Cutout systems match 22 mm operator hardware; M20/M25 glands align with cordset ranges. For standardized builds, match door stays and panel lights to the same supply voltage as PLC cabinets, and reuse PE/N bar kits across sizes for fewer spares. Where documentation is strict, engraved aluminum markers share the same pitch as the rail markers inside.

weidmuller electrical cabinets selection checklist for B2B buyers

  • Environment and IP: pick IP65–IP66 with stainless for washdown or coastal sites; IP30–IP55 is typical for dry plant rooms with low dust.
  • Size and depth: confirm device depth (breakers, soft starters, VFDs) and cable bend radius; add depth spacers if landing multi-core glands.
  • Mounting method: wall brackets for light loads; floor-standing with plinths for heavy drives and power supplies.
  • Thermal plan: use louvres or fan kits where in-cabinet dissipation exceeds plate rating; leave 20–30% spare space for heat and future I/O.
  • Rail and backplate kit: pre-cut TS35 rails and full backplates reduce onsite drilling; order extra end-stops for service loops.
  • Door and access: choose clear windows for status viewing; add door stays where instruments require hands-free reading.
  • Serviceability: specify internal LED lights, document pockets, and cable tie bases—cheap items that prevent rework.

Advantages of working with Bankoflamps

Individual B2B pricing with a personal account manager. Real-time stock visibility across EU warehouses and quotes in about an hour. Order fast by EAN/MPN, download up-to-date price lists with validity dates, and track lead times and status. We support post-payment up to 30 days for trusted clients and manage consolidated shipments to cut delivery costs. Serving France, the Baltics, Germany, Spain, Italy, Belgium, and the Netherlands.