Technical Information
| Item condition |
New |
| Manufacture name |
Weather station REG-K/4-gang, light grey |
| Brand |
Schneider Electric
|
| Categories |
Bus System Devices (KNX/Modbus)
|
| Country of origin* |
DE |
|
* The actual country of origin may differ depending on the delivery batch.
To confirm the specific country of origin, please contact your account manager.
|
| Bus system KNX |
Yes |
| Bus system radio frequent |
No |
| Bus system Powernet |
No |
| With bus connection |
Yes |
| Other bus systems |
None |
| Bus system LON |
No |
| Bus system KNX radio |
No |
| Radio frequent bidirectional |
No |
Packing details
| Packing level 1 |
3606485012346 |
| Packing level 2 |
3606485012344 |
Other Technical data
| Mounting method |
DRA (DIN-rail adapter) |
| Colour |
Grey |
| With heating |
No |
| Number of digital inputs |
0 |
| Analogue input |
Yes |
| RAL-number (similar) |
7035 |
| Weather station |
Yes |
| Degree of protection (IP) |
IP20 |
| With DCF77 |
Yes |
| Acoustic signal |
No |
Downloads
Description
The weather station records and processes analogue sensor signals such as wind speed, brightness, twilight, precipitation and a DCF-77 signal. Up to four analogue sensors and the DCF-77 weather combi-sensor can be connected in any combination. If DCF-77 weather combi-sensors are used, it is possible to access a pre-configured setting in the software. The measured values are converted by the weather station into 1 byte / 2 byte telegrams (EIS 6/5 value). This enables bus devices (visualisation software, measured value displays) to access the control processes, generate signals or control weather-dependent processes. Programming is performed using the ETS tool for the weather station. Functions:-Two limit values per sensor (not for rain). Connection of multiple wind sensors. 14 signals can be evaluated. Evaluation of DCF-77 time signal (date and time). Astro function. Logic operation controller for application of limit-value-dependent actions (even external). Shading of individual façade segments. Signal monitoring of the combi-sensors with object for the following protective measures. Checking the wind signal for conclusiveness with object for the following protective measures. Selective façade shading (for 4 façades) with adjustment of the basic brightness, façade alignment, angle of opening relative to the sun. External objects for intervention in basic brightness, angle of opening and limit values: -Alarm byte. -Continuity monitoring with report on the bus. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. Auxiliary voltage: AC 24 V (+/-10 %). Analogue inputs: 4. Current interface: 0-20 mA, 4-20 mA. Voltage interface: 0-1 V, 0-10 V. utputs: DC 24 V, 100 mA. Device width: 4 modules, approx. 72 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.