Register to unlock your exclusive B2B prices and start shopping. Sign up now!

Volta

Volta lighting portfolio for building upgrades and maintenance programs

Volta covers everyday replacement lines and project rollouts for retail, hospitality, office, and residential upgrades. The focus is predictable lumen output, stable colour quality, and broad availability in common bases and form factors.

Volta selection guide match lumen targets, not watts

Start with a broad scan in Volta lamps when you need fast filtering by base, shape, CCT, and lumen class. Replace on lumens to preserve brightness across technologies. Typical E27 replacements: 40 W ≈ 470 lm, 60 W ≈ 800 lm, 75 W ≈ 1050 lm, 100 W ≈ 1520 lm.

Volta incandescent for heritage ambience and full dimmer compatibility

For decorative fittings and legacy dimmers, source incandescent bulbs. They deliver instant full brightness, continuous dimming without artefacts, and warm colour rendering suited to heritage venues, restaurants, and boutique retail.

Volta LED lamps for energy savings and lower maintenance

Standardize on Volta LED lamps to cut energy and truck rolls. Match lumen output and beam angle, verify flicker performance, and confirm compatibility with leading or trailing edge dimmers. Prioritize CRI 90 where colour fidelity matters; CRI 80 is generally sufficient for corridors and back-of-house.

Volta LED lamps AI for smart control and analytics

Choose Volta LED lamps AI when you need connected control, scene profiles, or basic usage analytics without a full controls retrofit. Define network and security policies, latency needs for occupancy response, and fallback behaviour on network loss.

Volta E27 LED lamps for the most common socket in Europe

For pendants, table lamps, and bulkheads, specify Volta E27 LED lamps. Align CCT by room 2700 K hospitality, 3000 K mixed use, 4000 K task and verify thermal headroom in enclosed shades to maintain lifetime.

Engineering criteria for procurement and QA

  1. Colour quality and ambience
    Target CRI by zone CRI 90 for retail and dining, CRI 80 for offices and circulation. Keep a single CCT per zone for visual uniformity.
  2. Optics and glare
    Use opal globes in open luminaires to soften hotspots; clear glass for sparkle in decorative fixtures. Check beam spread in downlight retrofits to control UGR.
  3. Electrical and thermal limits
    Validate nominal voltage range and surge immunity on unstable mains. Confirm max case temperature in enclosed luminaires.
  4. Dimming and driver behaviour
    Confirm dimmer type, minimum load, low-level flicker, and multi-lamp stability on shared circuits.
  5. Lifetime and service plan
    Use L70 claims and switch-cycle ratings to set replacement intervals. In high access-cost areas, choose extended-life SKUs and maintain labelled spares by base and CCT.

Application playbooks with Volta

  • Hospitality and retail warm CCT, high CRI on merchandise and dining zones; decorative clear forms for feature pendants.
  • Offices and education neutral white, low glare, sensor compatibility, and stroboscopic limits for comfort.
  • Residential and public housing mix warm and neutral by room; standardize on E27 to simplify spares; use shatter-resistant designs in public corridors.

Compliance, documentation, and rollout

  • Keep CE and EN test summaries, EMC reports, and DoC in the QA pack.
  • Label cartons with barcodes and batch codes for traceability.
  • Acceptance tests per site lumen checks, CCT spot checks, dimmer behaviour, and fit tests in representative luminaires.

Why source Volta from Bank of Lamps

Bank of Lamps is a wholesale distributor with EU-wide delivery from a Latvia warehouse, real-time stock, bulk pricing, and consolidated multi-brand shipments. We help engineering and procurement align lumen targets, CCT policy, dimmer compatibility, and replenishment cycles across sites.

If helpful, I can turn this into a tender-ready bill of materials with lumen equivalence tables, CCT policy by zone, dimming compatibility notes, and reorder pack sizes.